Machine Calibration
8. Then the message “Next, Remove the Calibration Nozzle From Head 1. Click [Next]
for Moving Down Head. After Moving, Remove the Nozzle Manually” appears. Click
the <Next> button to remove the calibration tool from the nozzle-holder of Head #1
manually.
9. Form Head #2 to Head #6, perform calibration in the same manner as it was performed
for Head #1.
10. If the calibration procedure is completed for all heads normally, the result is displayed
as shown in the following figure. Click the <Update> button to apply the calibration
value.
14-62
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
11. The measurement result can be confirmed in the Head Offset dialog box.
Memo The range of the reference value for the ‘Head Offset Calibration’ are
as follows:
Head 1
X:-0.05mm~0.05mm, Y: -0.04mm~0.04mm
Head 2
X:29.95mm~30.05mm, Y: -0.04mm~0.04mm
Head 3
X:59.95mm~60.05mm, Y: -0.04mm~0.04mm
Head 4
X:89.95mm~90.05mm, Y: -0.04mm~0.04mm
Head 5
X:119.95mm~120.05mm, Y: -0.04mm~0.04mm
Head 6
X:149.95mm~150.05mm, Y: -0.04mm~0.04mm
14-63
Machine Calibration
14.3.7.7. Fly Camera Scale Calibration
This calibration is performed to find the scale and rotation offset of the fly-camera. In
order to calibrate the scale and rotation of the fly-camera, the ‘fix-camera calibration’ and
‘head Z-offset calibration’ must be performed in advance and the CNT20 Nozzle must be
used.
The following is the procedure to calibrate the ‘Fly-Camera Scale Calibration’
1. Click the <Nozzle Prepare> button and insert the CNT20 nozzle into the No. 1 hole of
the ANC manually.
If the <12. Fly Camera Scale> is clicked after selecting the <Automatic Next> check
box, calibration is performed for the selected gantry automatically.
If calibration is performed after selecting the <No Real Motion [Manual]> check box,
the nozzle is inserted into each head manually. Click the <Next> button to move onto
the next step.
If calibration is performed without selecting either the <Automatic> check box or
<Manual> check box, the nozzle is changed automatically for the currently selected
nozzle. Click the <Next> button to move onto the next step.
2. If the <12. Fly Camera Scale> button is clicked, the message box “First, We must Put
all Nozzles From Heads on Manually. To Move down Z Axis, Click [Next]” appears in
the message box. Click the <Next> button to move down the Z axis of the head in
order to remove all nozzles inserted in the nozzle-holder of the head manually.
3. Then, after the head assembly moves to the designated position, move all Z-axes
down. At this time, remove all inserted nozzles manually.