SM482PLUS_Admin(Eng_Ver2.8).pdf - 第182页

7-10 SM PLUS Administrator’s Guide Shows the unit system fo r the currently set it ems.  button Restores the modified part data to the data before modification.  button Displays the part registration status as a grade.…

100%1 / 604
7-9
Part Registration
7.2.1. Screen Configuration
1: Title
2: Vision Window
3: Part parameters
‘Title’ area
<Select Head> button
Selects the head to pick the part.
<Image Refresh> button
Refresh the part image displayed in the vision window.
<Machine Message> button
Executes the dialog box that can check an error message generated in the machine.
button
It is possible to input further explanations for the corresponding part.
caption button
7-10
SM PLUS Administrator’s Guide
Shows the unit system for the currently set items.
button
Restores the modified part data to the data before modification.
button
Displays the part registration status as a grade.
Refers to the part that has been used for PCB production.
Refers to the part that passed the part recognition test in the machine MMI and
T-ELITE .
Refers to the part temporarily registered when creating a PCB program in the
T-Solution. It is copied from the standard part DB.
<Save> button
Saves the edited part data and closes the dialog box.
<Cancel> button
Closes the dialog box without saving the edited part data.
7-11
Part Registration
‘Vision Window’ area
Displays the part image and part shape.
button
When this button is selected, it is possible to move the vision image using the
mouse.
/ button
Zooms in/out the vision image.
button
Shows the vision image at 100% in size. The image size is indicated as a
percentage(%) at the top right of the vision window.
button
Sets the grid interval in the vision window. The unit of the set value is mm.
button
Clicking this button will show the vision image in the following order:
Actual Image Black and Image Edge Image Actual Image