SM482PLUS_Admin(Eng_Ver2.8).pdf - 第408页
14-36 Multi-Functional Placer SM482( L) PLUS Administrator’s Guide <Scale T each...> button T eaches the Y of fset of the conveyor fiducial mark. Figure14.11 “Scale Teach” dialog box <W idth (mm)> group D…

14-35
Machine Calibration
fiducial mark selected from the Grid group.
<Get> button
Applys the coordinate value of the current position as the selected fiducial mark
position.
<Fiducial Teach…> button
Teaches the fiducial marks of the selected Station. Please refer to“6.3 Fiducial Mark
Setup” for more information.
<Edge Offset Teach…> button
Used to measure the offset between the fiducial mark and edge accurately.
Figure14.10 “Teach Rails Edges” dialog box
<Edge Offset> edit box
Means the distance from the center of the fiducial mark to the edge of the rail.
Teaching must be performed after selecting this point using a mouse.
<Move> button
The <Move Cam> button can be clicked after first selecting a station and next
selecting the <Edge Offset> edit box. Then the downward camera (Fiducial
Camera) is moved to the center of the selected fiducial mark of the selected
station.
<Get> button
Apply the coordinate value of the current position as the selected fiducial mark
position.
<Light> button
Set the lighting value. Set the value by adjusting the sliding bar.
<Update> button
Applies the changed value and closes the dialog box.

14-36
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
<Scale Teach...> button
Teaches the Y offset of the conveyor fiducial mark.
Figure14.11 “Scale Teach” dialog box
<Width (mm)> group
Displays the conveyor width provided by default for calibration.
<Fiducial Position> group
Displays the XY coordinates of the conveyor fiducial mark set by the MMI.
<Offset (mm)> group
Displays the Y value of the conveyor fiducial machine measured by the actual
machine as well as the offset of the Y value set by the MMI.
<Final Offset ->> group
A: Y offset when the conveyor width is 50mm
B: Y offset when the conveyor width is 344mm
Final Offset = B-A
<Move> Button
Moves the fiducial camera to the conveyor position selected from the <Fiducial
Position> group.
<Scan> Button
Scans the fiducial mark of the conveyor selected from the <Fiducial Position>
group and displays the Y offset in the <Offset (mm)> group.
<Auto> Button
Executes the Y offset teaching process of the conveyor fiducial mark
automatically.
<Light> Button
Sets the lighting value. Adjust the corresponding slide bar to set the lighting value.
<Update> Button
Applies changed values and closes the dialog box.

14-37
Machine Calibration
Conveyor Calibration method is as follows.
1. “Click the <Home All> button in the “Conveyor Calibration” dialog box.
2. Select <StationF2> in the <Station> combo box to enable <Fiducial Teach...> and
<Edge Offset Teach...>.
3. Click the <Fiducial Teach…> button to teach the fiducial marks of the selected station
accurately and click the <Tuning> button to scan the position accurately.
4. Click the <Update> button to update the information on the fiducial mark position.