Preface xxi to the driving systems such as m o t or. I t i s u s e d to p u t the machine into the standby status after power-up. ‘EMG (emer gency stop)’ switch can be pressed to release the standby state.  RESET Button…

100%1 / 604
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
xx
Warning If power supply is cut off suddenly, it could result in the
damage of data and machine.
And the machine might be damaged due to abnormal
operation when power is supplied again.Before turning off
power, be sure to end the MMI, turn off the main switch,
then turn on the main switch after 5-10 seconds.
Safeguard override key switch
This is a key switch that can be operated artificially to prevent the door switch from
operating. It should be used limitedly only when performing initial setting or
maintenance of the machine.
Danger The Safeguard override key switch must be used by the
designated responsible personnel. It must be carefully used
for machine operation. Failure to do so may result in death
or serious personal injury if the operator approached the
drive with the safety cover Open.
Operation Panel (OP Panel)
Consists of Buttons for machine operation and the emergency stop switch.
STOP Button (Red Color)
This is a Button for temporary stopping of the operation. Automatic operation of
this machine is temporarily stopped if this Button is pressed. If this Button is
pressed while the placement is in progress, the operation is stopped after the
present operation is completed. This Button can also be used for turning off alarm
sound due to an error.
START Button (Green Color)
This is a switch for initiating the operation of this machine. Automatic operation is
initiated if this switch is pressed.
Warning Pressing the START Button without checking the presence
of worker nearby could cause injury.Be sure to check if
there is any worker near the machine before pressing the
START Button.
READY Button
This is a switch for initiating the operation of this machine. The power is supplied
Preface
xxi
to the driving systems such as motor. It is used to put the machine into the standby
status after power-up. ‘EMG (emergency stop)’ switch can be pressed to release
the standby state.
RESET Button (Blue Color)
Used to stop production in a machine that has paused automatic production or to
release the error in a machine that has been paused due to an error. Pressing this
Button in a machine to which an error has occurred will change the state of the
machine from 'FREEZE' or 'EMER' to 'IDLE'. The ‘Reset’ Button cannot be
activated during automatic operation of this machine.
F/R SELECTS Button
It is the Button that determines which one of the front operation panel and rear
operation panel will have the control authority. Whether or not the corresponding
operation panel has the control authority depends on the status of this Button.
When initializing the machine, the front is set to have right for control by default.
(Front side by default.)
If the select Button is pressed and maintained for a second, the LED Button is
turned on and the right for control is transferred to the rear side. It takes 0.3~1
seconds to change the right for control from the front OP panel to the rear OP
panel. The same applies when changing the right for control reversely.
The same applies for the rear side. The following table shows this briefly.
Feeder change Button
The Button used to replace the feeders on the front and rear feeder base. When this
Button is pressed, the head unit of the machine come to the safety zone for easy
feeder change.
EMG (Emergency Stop) Switch
This is an emergency stop switch. Operation of this machine is immediately
suspended if this switch is pressed in case of an emergency.
Supply of all powers except for the power to a computer is ceased. The emergency
stop status can be released by turning the ‘EMG’ switch in the direction of the
arrow and pressing the RESET Button.
Right for control
Front panel select
Button LED status
Rear panel select
Button LED status
Front On Off
Rear On Off
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
xxii
About Warranty
The warranty is issued to cover the following machine faults and malfunctions.
The warranty terms and conditions agreed to at the purchase of the product precedes
the general terms above.
What is covered by
the warranty
Hanwha Precision Machinery Co., LTD. provides free warranty
services within the warranty period if the product fails to operate
properly under normal operating conditions due to defective materials
or problems originating from the manufacturing process.
Time period of the
warranty
The term of this warranty shall expire for any of the following cases.
Warranty expires 24 months after shipment or 24 months after
installation.
However, if there is more than one term of expiration of the warranty
period, the terms that come later will be applied.
What is not
covered by the
warranty
Product warranty does not cover the following cases.
If the stored data is lost due to damage to the HDD or SSD
(regular backup is recommended.)
When data is damaged due to system malfunction or virus
infection due to the execution of a program not related to the
operation of the product
Natural changes over time or natural wear from the use of the
product (discoloration of paints or coats, wears on consumable
parts, etc.)
Sensory conditions that do not affect the quality and functions of
the product (operating noise from the controller or motor, etc.)
Defects due to ambient conditions (moisture, impurities, dust on
the machine, oil mist, etc.).
Malfunctions caused by misuse
Natural disasters such as earthquakes, storms, flooding, lightning,
accidents, or fire
Unauthorized modification of the product
Failure to back up the data stored in the machine.
When using non-genuine parts or accessories
Lack of proper repairs or maintenance work(Includes the use of
non-specified lubricants)
Adjustment of the product by unauthorized parties