Machine Calibration
14.1.4. “Fly-Fix Offset” tab dialog box
Sets the Fly-Fix offset for each head. Data in this dialog box is updated automatically if the
Fly to Fix Offset Calibration is executed during camera calibration and the result value is
reflected.
Figure14.4 “Fly-Fix Offset” tab dialog box
<Device> combo box
Sets the Fly-Fix offset for each head.
<Fly To Fix Offset>
<Degree> column
Sets the Fly-Fix offset by degree at 45 degree interval.
<X, Y> column
Sets the Fly-Fix offset of X, Y.
<Fly Run Out Offset>
<Degree> column
Fly-Fix offset for each angle can be setup at the interval of 45 degrees.
<X, Y> column
Sets the Fly Run Out offset of X, Y.
<Clear data for this Head> button
Deletes Fly-Fix offset data of the selected head. Used when not applying the Fly-Fix
offset on the head. Data cannot be restored once it has been deleted. To apply the Fly-
Fix offset, the camera calibration must be performed again.

14-8
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
<Update> button
Transmits the change data to the equipment and closes the dialog box.
<Cancel> button
Ignores the change data and closes the dialog box.
14.1.5. “Mount Offset” tab dialog box
Sets the placement offset for each head.
Figure14.5 “Mount Offset” tab dialog box
1: Grid group
<Fly Cam> / <Fix 1 Cam> option button area
Sets the placement offset for each camera.
<Device> combo box
Sets the placement offset for each head.
<Grid> group
Sets the placement offset by degree at 45 degree interval.
<Degree> column
<Offset-X, Y, R> column
Sets the placement offset of X, Yand R.
<Clear data for this Head> button
Deletes placement offset data of the selected head.

14-9
Machine Calibration
<Clear all data for this Camera> button
Able to delete the placement offset data of all the heads corresponding to the selected
camera.
<Import> Button
If you click this button and select a previously created print file, the offset extracted
from the testing machine will be applied to the mounting offset of the current
equipment.
However, you must click the <Update> button to apply the
offset extracted from testing for the equipment.
<Export> Button
Click this button to export the mounting offset of the current equipment as a print file.
<Add Offset> group
It is possible to apply X, Y and R placement offsets collectively to all heads.
This function is used at the factory. Users must not apply the offsets at their own
discretion.
<Update> button
Transmits the change data to the equipment and closes the dialog box.
<Cancel> button
Ignores the change data and closes the dialog box.