14-70 Multi-Functional Placer SM482( L) PLUS Administrator’s Guide 8. Then the message “Next, Remove the Calibra tion T ool From Head 1. Click [Next] for Moving Down Head. After Moving, Remove the T ool Manually” appears…

100%1 / 604
14-69
Machine Calibration
5. The message “Up to Align Height and Mirror Close, Click [Next].” Appears, Click
[Next] button.
6. Next, Head 1 moves up to the align height of the Fly Camera and the mirror is closed.
Then the message, “Calibration is Prepared. To Calibrate, Click [Next]” is displayed in
the message window. At this time select the ‘Fly Cam1‘ in the <Target Camera>
combo box and in the ‘Light Control‘ dialog box, adjust the brightness of the lighting
so that the ‘Fiducial Mark’ on the CNT20 nozzle can be clearly seen in the ‘SMVision‘
window. Then click the <Next> button.
7. The calibration is performed automatically. If it is completed, the calibration result is
displayed as shown in the following figure. Click the <Next> button.
14-70
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
8. Then the message “Next, Remove the Calibration Tool From Head 1. Click [Next] for
Moving Down Head. After Moving, Remove the Tool Manually” appears. Click the
<Next> button to remove the CNT20 nozzle from the nozzle-holder of Head #1
manually.
9. From Head #2 to Head #6, perform calibration in the same manner as it was performed
for Head #1.
If the calibration procedure is completed for all heads normally, the result is displayed
as shown in the following figure. Click the <Update> button to apply the calibration
value.
10. The result value can be confirmed in the Camera dialog box in the System Setup
menu.
14-71
Machine Calibration
Memo The reference values for the calibration of the Fly Camera Offset is as
follows. (FOV 25 MEGA) [Unit : X(mm), Y (mm), R (°)]
Offset X: -0.60 ~ 0.60
Offset Y: -0.60 ~ 0.60
Offset R: -1.0 ~ 1.0
The reference values for the calibration of the Head Reference
Fiducial Offset is as follows. [Unit : X(mm), Y (mm)]
Offset X: -0.50 ~ 0.50
Offset Y: -0.50 ~ 0.50