14-67 Machine Calibration ScaleY : 50.00~54.16 ( μ m/pixel)

14-66
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
12. The result value can be confirmed in the Camera dialog box in the System Setup
menu.
Memo The range of the reference values for the ‘fly-camera calibration’ is as
follows:.
FOV 16 (HEXA)
ScaleX: 14.30~15.70 (μm/pixel)
ScaleY: 14.30~15.70 (μm/pixel)
FOV 25 (HEXA)
ScaleX: 22.10~24.10 (μm/pixel)
ScaleY: 22.10~24.10 (μm/pixel)
FOV 16 (MEGA)
ScaleX: 15.15~16.59 (μm/pixel)
ScaleY: 15.15~16.59 (μm/pixel)
FOV 25 (MEGA)
ScaleX: 23.00~25.00 (μm/pixel)
ScaleY: 23.00~25.00 (μm/pixel)
FOV 16
ScaleX: 32.82~35.94 (μm/pixel)
ScaleY: 32.82~35.94 (μm/pixel)
FOV 25
ScaleX: 50.00~54.16 (μm/pixel)

14-67
Machine Calibration
ScaleY: 50.00~54.16 (μm/pixel)

14-68
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
14.3.7.8. Fly Camera Offset Calibration
The following is the procedure to calibrate the offset of the fly Camera. In order to perform
‘Fly-Camera Offset Calibration’, the ‘Fly-Camera Scale Calibration’ and ‘Head Z-Offset
Calibration’ must be performed first and the CNT20 nozzle must be used.
The following is the procedure to calibrate the ‘Fly-Camera to Offset.
1. Click the <Nozzle Prepare> button and insert the CNT20 nozzle into the No. 1 hole of
the ANC manually.
2. If the <13. Fly Camera Offset > is clicked after selecting the <Automatic Next> check
box, calibration is performed for the selected gantry automatically.
If calibration is performed after selecting the <No Real Motion [Manual]> check box,
the nozzle is inserted into each head manually. Click the <Next> button to move onto
the next step.
If calibration is performed without selecting either the <Automatic> check box or
<Manual> check box, the nozzle is changed automatically for the currently selected
nozzle. Click the <Next> button to move onto the next step.
If the <13. Fly Camera Offset> button is selected, the message, “First, We must Put all
Nozzles from Heads manually. To Move down Z Axis, Click [Next]” is displayed in
the message window. Then click the <Next> button to move down the Z-axis of the
head in order to manually remove all the nozzles installed on the head.
3. Then, after the head assembly moves to the designated position, move all Z-axes
down. At this time, remove all inserted nozzles manually.
4. Then the message “Next Attach the Calibration Tool to Head 1. Click [Next] for
Moving Down Head. After Moving, Attach the Calibration Nozzle to head Manually”
appears. Click the <Next> button after manually inserting the CNT20 nozzle in the
nozzle holder of Head 1.