Administrator’s Guide(CP45FV) Eng.pdf - 第165页
S tep Pr ogramming 9-13 When the <OK> button is clicked afte r selecting a component, th e name of the selected file is inputted in the <1.Part Name> edit box. Select the <Package Group> correspon…

Samsung Component Placer CP45FV Series Administrator’s Guide
The component that has already been registered in the Local Part DB is
registered automatically as can be seen above. Click the <New Part…>
button and execute the <Part Edit> dialog box.
When the
button is clicked, the unregistered part list is displayed as
shown in the following figure.
9-12

Step Programming
9-13
When the <OK> button is clicked after selecting a component, the name of
the selected file is inputted in the <1.Part Name> edit box.
Select the <Package Group> corresponding to the selected component and
revise the component profile according to the selected component.
Click the <Register> button to register the component to the PCB Part List.

Samsung Component Placer CP45FV Series Administrator’s Guide
When all the unregistered part information is registered, they are displayed as
follows.
<Export…> button
Converts the step data created by this machine into other format(SSA Format) ASCII
File. When this button is clicked on, the following dialog box is displayed.
When the “Save” button is clicked on after the ASCII File name has been set, converts
the step data into SSA format and saves the data under the set file name.
<Cancel> button
Cancels the edited data.
9-14