Administrator’s Guide(CP45FV) Eng.pdf - 第246页

Samsung Component Placer CP45FV Administrator ’ s Guide same function as selected by the manual tool in the V iew menu. The following is the procedure to perform calibration of the positions of the Z-axis and mirror axis…

100%1 / 321
Machine Calibration
15-7
(FOV 25) (FOV15)
<When the nozzle is mounted on the head>
(FOV 25) (FOV 15)
<When the nozzle is not mounted on the head>
<Manual Tools> button
Clicking this button will execute the Manual Controldialog box by performing the
Samsung Component Placer CP45FV Administrators Guide
same function as selected by the manual tool in the View menu.
The following is the procedure to perform calibration of the positions of the Z-axis
and mirror axis, nozzle recognition condition and lighting condition. Perform this
procedure from head mirror teaching to light count teaching in order;
Head Mirror Teaching
The default value is 57.
1. Select the Current Position in the View menu to execute the Position dialog
box.
2. Click the <Manual Tools> button in the Nozzle Check Setting Tab dialog
box to execute the Manual Controldialog box.
3. Select Mirror in the <Axis> combo box of the Axis Tab dialog box.
15-8
Machine Calibration
15-9
4. Select the Camera corresponding to the head in the Camera Tab dialog box.
5. Move the mirror axis using the teaching box so that the bottom center of the
LED of the corresponding camera falls on the fourth scale from the bottom
of the cross hair on the vision monitor.
When using the FOV
25mm Fly Camera
When using the FOV 25mm Fly Camera, align the LED bottom line with the