Administrator’s Guide(CP45FV) Eng.pdf - 第229页
Placement T est 14-15 Click the <OK> button to apply the changed lighting value to the corresponding component profile, and click the <Part Align> button to perform co mponent recognition again. If th…

Samsung Component Placer CP45FV Administrator’s Guide
If the component recognition is failed, click the <Edit Part Info> button to change the
Align Data for the corresponding component.
At this time, if the component is not clearly seen on the vision monitor as in the
above figure, click the <Light Control> button in the following dialog box to adjust
the lighting by controlling the slide bar so that the component shape can be seen
clearly.
14-14

Placement Test
14-15
Click the <OK> button to apply the changed lighting value to the corresponding
component profile, and click the <Part Align> button to perform component
recognition again.
If the component is still not recognized, click the <Edit Part Info> button again to
change the Align Data for the corresponding component.
For more details concerning the component profile change, refer to the “7.1 Part
[F3](page 7-1)”.
Once the component profile is changed, click the <OK> button in the “Edit the
selected part” dialog box to apply the change, and click the <Part Align> button to
perform component recognition again.
14.3.5. Component Placement Error
Occurs in the following cases; the nozzle has a defect; the component placement height
setup is incorrect; the air blow or vacuum function is not working properly; and the
placement related parameter setup is inappropriate.
When the nozzle has defect
Error occurs if a standard genuine nozzle is not used or the nozzle is clogged with
foreign matter or the nozzle suitable to the component is not used.

Samsung Component Placer CP45FV Administrator’s Guide
If the standard genuine nozzle is not used, vacuum is not created properly so that
the component may not be picked up. Therefore, a standard genuine nozzle must
be used.
When the nozzle is clogged, clean the nozzle referring to the “2.1 Nozzle” of the
Maintenance Reference.
Use the nozzle suitable to the component.
When the component placement height setup is incorrect.
The component thickness is set incorrectly in the component profile.
The Backup Pin position setup is inappropriate or there is a problem with the
flatness of the PCB due to improper clamping.
When the air blow or vacuum function is not working properly and the placement
related parameter setup is inappropriate.
A B C
Case A: Air blow is setup normally. The air volume and the delay are accurate.
Case B: The air volume is too much or the delay is too long.
Case C: The air volume is too small or the delay is too short. In such case, the
placement error occurred due to the component being lifted up to the nozzle tip
prior to placement of the component.
The following figure shows the setup of the air blow and vacuum for component
placement.
14-16