Machine Calibration
15-19
Select the items to calibrate.
<Move Camera> button
Calibrates the move camera (Fiducial Camera) in combination with the
Calibration Plate.
The Move Camera (Fiducial Camera) calibration procedure is as follows;
1. If a nozzle is mounted on the head, clear the select “No real motion” and
click on Put all nozzle”. Perform calibration with a nozzle not mounted
on the head.
2. Click the <PCB In> button in the Board dialog box of the PCB Edit
menu tool bar and fix the Calibration Plate on the placement position.
3. Select the Camera [F9] in the SysSetup menu tool bar and execute the
Camera Setting dialog box.
4. Click the <Calibration> button in the Camera Setting dialog box to
display Auto Calibration dialogboxand click the <Move Camera> button
in the menu group.
5. If the “Prepare PCB for Calibration” message is displayed, click the
<Next> button since the calibration plate has been fixed on the
placement position.
6. If the message, “Move Head Assembly by jogbox. To adjust between
Fiducial move camera to Fiducial mark's center on the PCB” is
displayed, align the cross hair center of the camera screen with the plate
center and click the <Next> button.
7. The machine recognizes the black circle on the plate moving up and
down and left and right.
8. When the calibration is completed normally, the OLD data and New data
window are displayed. The data may be updated or canceled.
If an error occurs as a result of the outline of the black circle on the plate
not being clearly recognized during calibration, adjust the brightness of
the lighting so that the circle outline is clearly recognized. Then perform
the calibration again.
<Head[Fly] Camera> button
Calibrates the Fly Camera in combination with the Fly Camera Calibration
Tool.
The Fly Camera calibration procedure is as follows;
1. Remove the hex bolt in the area shown in the following figure.
Samsung Component Placer CP45FV Administrators Guide
2. Remove the mirror cover in the area shown in the above figure.
When removing the cover, take care to ensure that it does not collide with the mirror.
3. If there is a nozzle on the head, click the <Put> button in the ANC dialog
box and place the nozzle on the pocket.
4. Select the Camera [F9] in the SysSetup menu tool bar and execute the
Camera Setting dialog box.
5. Click the <Calibration> button in the Camera Setting dialog box to
display the Auto Calibration dialog box and click the <Head [Fly]
Camera> button in the menu area.
6. If the message, “First, we must put all nozzles from heads manually. To
moving down Z axis, Click [Next].is displayed, click the <Next>
button in the Auto Calibration dialog box.
7. If a message, Next, Mirror will close. To close, Click [Next]. is
displayed, click the <Next> button in the Auto Calibration dialog box.
Since the mirror moves inward by about 45 degrees, take care not to cause any safety
related accidents.
8. If the message,Setting the fly camera calibration tools on conveyor is
displayed, install the calibration tool on the top surface of the conveyor
as shown below. Then click the <Next> button.
15-20
Machine Calibration
15-21
Install the calibration tool so that it is aligned with the inner surface.
Install it perpendicular to the conveyor.
9. Move the X and Y axes slowly using the teaching box to adjust the
installed calibration tool so that it can be seen through No. 1 Fly Camera
(Head1 Cam).
10. If the message,Adjust between vision screen center to mark centeris
displayed, align the center of the black circle on the calibration tool with
the cross hair center of the vision screen facing the left vision monitor
screen. Then click the <Next> button.
11. At this time, calibration is performed with X and Y axes moving. If this
procedure is completed normally, the calibration procedure for the Fly
Camera of the Head2 is performed automatically.
12. Select the calibration camera in the <Target Camera> combo box and
perform calibration of the Fly Camera of the heads up to Head6 in the
same manner.
13. If the message,Removing the tool on the conveyor finished, then click
[Next] is displayed, remove the calibration tool installed on the
conveyor and click the <Next> button.
If the calibration tool is not removed, it may collide with the mirror
when the mirror is closed.