Administrator’s Guide(CP45FV) Eng.pdf - 第304页

Samsung Component Placer CP45FV Administrator ’ Guide Displays the vacuum level that considers the nozzle to be ch oked up before component pickups. <V acuum Check Level>  Displays the vacuum level that consid ers…

100%1 / 321
Diagnosis
17-7
17.4. Vacuum [F5]
Checks the air pressure status of the head.
When this button is clicked on, the following dialog box is displayed.
Figure 17-9. Diagnosis : Vacuum Diagnosis dialog box
<Head Vacuum level> group
Displays the vacuum level of each head and controls the vacuum generator.
<Current Level>
Displays the current vacuum level of each head.
<OFF> button
Controls the vacuum generator of each head.
When OFF is displayed, pressing this button turns off the vacuum generator
and displays ON on the button. When ON is displayed, pressing this button
turns on the vacuum generator and displays OFF on the button.
<Reference Level> group
When the vacuum level is used as a criteria for determining component pickups by
each head, displays the standard value.
<Close Level>
Display the vacuum level of each head when the nozzle is stuck fast to the Check
PAD.
<Open Level>
Displays the vacuum level of each head when the nozzle is open.
<Check Level > group
Displays the vacuum level that is used as a criteria for determining component
pickups.
<Choke Check Level>
Samsung Component Placer CP45FV Administrator Guide
Displays the vacuum level that considers the nozzle to be choked up before
component pickups.
<Vacuum Check Level>
Displays the vacuum level that considers a pickups to be successful after
component pickups.
<Check> button
Measures the time taken until the vacuum level is stabilized. When this button is
clicked on, the following screen is displayed.
<Close> button
Closes the dialog box.
17-8
Diagnosis
17-9
17.5. Jogbox [F6]
Checks the operation of the Jog Box. When this button is clicked on, the following dialog
box is displayed.
When each button in the actual Jog Box is operated, displays the operation status.
Figure 17-10. Diagnosis : Jog Box Diagnosis dialog box
<Speed LED All> button
Turns ON/OFF all Speed LEDs.
<Mode LED All> button
Turns ON/OFF all Mode LEDs.
<Axis LED All> button
Turns ON/OFF all Axis LEDs.
<Head LED All> button
Turns ON/OFF all Head LEDs.
<All LED> button
Turns ON/OGG all LEDs.
<Close> button
Closes the dialog box.