Administrator’s Guide(CP45FV) Eng.pdf - 第232页

Samsung Component Placer CP45FV Administrator ’ s Guide Changing placement position   If the corresponding position deviates of f the actual placement center , change the coordinate of the placement position once again…

100%1 / 321
Placement Test
14-17
Please refer to Figure 7-6 (Page 7-6)" .
14.4. Position Correction
After the placement test, any error related to the placement position shall be solved
through position calibration.
14.4.1. Specific Placement Point Position Error
Even though the components were placed on the PCB normally, placement position error
may occur at one specific point and it may have been caused by the incorrect coordinate
of the corresponding position.
Checking position on the PCB
Move the “Move Camera” to the actual position on the PCB corresponding to the
coordinate of the placement point where placement position error has occurred, and
check the placement position through the vision monitor.
Samsung Component Placer CP45FV Administrators Guide
Changing placement position
If the corresponding position deviates off the actual placement center, change the
coordinate of the placement position once again by teaching the placement point.
14.4.2. Movement of Specific Component Placement Position
When placing the specific component, if the position where the actual component is
placed is deviated from the placement position in the same pattern, the component profile
may have a problem.
Component profile change
Check Align Data in the corresponding component profile. Check if the size and
thickness of the actual component has been entered incorrectly. If so, change the error.
14.4.3. Change of Placement Position on the Entire Block or Some Part of the
Block
If placement position is moved for all components placed on the PCB in the same form,
an error may occur in the PCB origin, initial theta or fiducial mark position.
PCB Origin Error
If the coordinate of the PCB origin is setup incorrectly, the coordinates of all
placement points are likewise setup differently from the actual positions.
Move the “Move Camera” to the PCB Origin position set in the Board dialog box to
check for any error and if there is, change the coordinate.
14-18
Placement Test
14-19
Initial Theta Error
If all the components placed on the PCB are being rotated in the same direction, it is
because the PCB is not parallel with the coordinate system of the machine due to
some problem with the PCB.
Teach the Initial Theta of the PCB to check if its value is zero (0), otherwise, change
the PCB and perform the placement test again.
Fiducial Mark Position Error
If there is even a slight error in the coordinate of the fiducial mark center, it causes
slight error to the coordinate of the placement position.