<Fiducial Mark…> button
If there is a fiducial mark on the PCB, set the position of the fiducial mark and mark
data. When this button is clicked on, the following dialog box is displayed.
Figure 6-12. Fiducial Position & Mark dialog box (When the Position Type is None)
<1. Position Type> combo box
Select the number of fiducial marks. Available numbers are as follows.
None: No fiducial mark.
1 Panel: 1 fiducial mark for PCB correction.
2 Panel: 2 fiducial marks for PCB correction.
3 Panel: 3 fiducial marks for PCB correction.
1 Array: 1 fiducial mark for Array PCB correction in each Array PCB.
2 Array: 2 fiducial marks for Array PCB correction in each Array PCB.
3 Array: 3 fiducial marks for Array PCB correction in each Array PCB.
<2. Mark Position> group
If <Position Type> is not None, the number of data corresponding to the
number of fiducial marks selected are generated. For example, when 2 Panel is
selected, the following dialog box is displayed.
6-10
Board Definition
6-11
Figure 6-13. Fiducial Position & Mark dialog box (When the Position Type is 2
Panel)
<No> column
A serial number of the position of fiducial mark.
<X> column
The X position value of fiducial mark.
<Y> column
The Y position value of fiducial mark.
<Mark> column
The mark ID value of fiducial mark. This value must be set from a series of
numbers in <5. Mark List>.
<3. Inspection Device> combo box
Select the device to inspect the fiducial mark. Available devices are as follows.
Vision: Recognizes with the move camera(fiducial camera) in the head assembly.
<4. Teach> group
Used to move the head assembly to the designated position by rotating the
driving shaft of the X and Y-axes motors or obtain the current position of the
shafts of the X and Y-axes motors.
<Device> combo box
Selects the corresponding device to move the head assembly by rotating the
driving shafts of the X and Y motors or obtains the current coordinate of the
device to be selected. Available devices are as follows;
Move Cam: Selects Teaching Camera.
Head1: Selects Head 1.
Samsung Component Placer CP45FV Series Administrators Guide
Head2: Selects Head 2.
Head3: Selects Head 3.
Head4: Selects Head 4.
Head5: Selects Head 5.
Head6: Selects Head 6.
Beam: Selects Beam.
<Move> button
Moves the head assembly by rotating the shafts of the X, Y-axes driving
motors using the device selected from the <Device> combo box. Before
executing Move, the cell in the grid corresponding to the desired position
must be clicked on with a mouse.
<Get> button
Reads in the current position of the XY axis selected in <Device> combo box.
Before executing Get, the cell in the grid corresponding to the desired
position must be clicked on with a mouse.
<OK> button
Saves the fiducial mark data and closes the Fiducial Position & Mark dialog
box.
<Cancel> button
Closes the Fiducial Position & Mark dialog box without saving the fiducial
mark data.
<Scan> button
Executes a scan test on the set fiducial mark. The scan test inspects the actual
mark by using the set fiducial mark position and mark data and displays the
result as follows.
The position of the fiducial mark displayed on the above screen is the position of
the mark obtained through the scan test. If you want to update the value, click on
Yes, if not click on No.
6-12