Administrator’s Guide(CP45FV) Eng.pdf - 第236页

Samsung Component Placer CP45FV Administrator ’ s Guide Occurs when placement cannot be perfo rmed properly due to an air blow and va cuum function problem with the specific head . Select the V acuum submenu of the Diagn…

100%1 / 321
Placement Test
14-21
Teach the origin point of the Array PCB 1. Pressing the Enter key after teaching will
display the following screen.
1
St
Pt.
2
nd
Pt.
Teach the origin point of the Array PCB that is at the position that can determine the
offset. Pressing the Enter key after teaching will display the following screen.
If the “Enter” key is pressed, the teaching of the Array PCB offset is completed.
14.4.4. Placement Error of the Component Placed Using Specific Head
If a placement error occurs only to the component placed using a specific head, it may
have occurred due to a problem with the head.
Air blow and vacuum function problem of a specific head
Samsung Component Placer CP45FV Administrators Guide
Occurs when placement cannot be performed properly due to an air blow and vacuum
function problem with the specific head. Select the Vacuum submenu of the
Diagnosis menu to check the air blow and vacuum function.
Spindle problem of a specific head
The placement position may be distorted due to mechanical error of the specific head
spindle. In such case if the problem is found to have occurred due to a mechanical
error, the spindle must be replaced.
14-22
Calibration & Setup