NPM–W 2 EJM7DE-MB-02 -1T-00 Nzl Point Abno rmal Error Nzl Hei ght Range Ov (VLC) Nzl Height Det Err (VLC) Error Message Troubleshooting 2-1-3 Single stop er r or 17 Error Code Error Message Cause Inspection and Solution …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Threshold set err
(VLC)
Comm. status err
(VLC)
Sensor abnormality
(VLC)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Camera is blocked entirely
or partly.
2) Optical axis is displaced.
3) Failure of vertical line
camera detected.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Since the sensor is blocked,
remove any foreign body. Wipe
away any dirt from the lens if it is
dirty. If there is no foreign body,
check the connection of connector.
2) Adjust the optical axis of the
sensor.
3) Check the situation of the error
occurred and error message, and
contact PFSC.
40400
Communication status error
detected in issuing command.
(Single stop error occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
40401
Nozzle height offset is
beyond the threshold value.
Pre-scanning setting of the
vertical line camera could not
be made.
(Single stop error occurred.)
The offset value of the nozzle height
detection is not correct. Calibrate
the origin offset Z-axis and vertical
line camera.
40402
2-1-3-31
NPM–W2 EJM7DE-MB-02-1T-00
Nzl Point Abnormal Error
Nzl Height Range Ov
(VLC)
Nzl Height Det Err
(VLC)
Error
Message
Troubleshooting
2-1-3
Single stop error 17
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Measured nozzles and
measurement result
nozzles do not agree.
2) Measurement result is out
of output value.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the mounting condition of
the nozzle.
2) Make sure that there is no foreign
body on the lens of the vertical line
camera and diagonal line on the
emitter and detector sides of the
laser. Calibrate the origin offset Z-
axis and vertical line camera.
40403
Any of the following causes
is likely:
1) Difference between nozzle
detection result and nozzle
length exceeded ±0.050
mm.
2) Nozzle recognition height
and optical axis of the
vertical line camera are
displaced.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the nozzle length.
2) Calibrate the origin offset Z-axis
and vertical line camera.
40404
Tip of the nozzle is not planar.
(Single stop error occurred.)
Check the tip of the nozzle and
clean it. Replace the faulty nozzle.
40405
2-1-3-32
NPM–W2 EJM7DE-MB-02-1T-00
Shape of Parts err
(VLC)
Part Thick range ov
(VLC)
Part Thick det err
(VLC)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Measured nozzles and
measurement result
nozzles do not agree.
Scanning status of
measured component
affects the scan of other
nozzles.
2) Measurement result is out
of effective range of output
value of the vertical line
camera.
(Single stop error occurred.)
Make sure the component is set
properly and correct values of the
component data (component
dimensions, etc.) are set.
40406
Component thickness
measurement result is
beyond the threshold value of
thickness tolerance.
(Single stop error occurred.)
Check the upper and lower limits of
the thickness tolerance in the
mounting condition data of
component data.
40407
Invalid component pickup
status.
(Single stop error occurred.)
Check the component data
(component dimensions, etc.).Check
the pickup condition.
40408