N7201A618E00_0309.pdf - 第37页

NPM–W 2 EJM7DE-MB-02 -1T-00 3D Sensor Connectio n Supply A Cover Open Solutions to errors Error Code Error Message Cause Inspection and Solution Supply side door is open. (Self-di agnosis erro r occurred. ) Take measures…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Production End Status
Detect
Bulk Changeover Cart
Insert Error
Feed section connect
error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 6
Error Code
Error Message
Cause Inspection and Solution
Feeder cart connector not
connected.
(Self-diagnosis error
occurred.)
Connect the feeder cart
again.Choose [Machine] - [Adjust] -
[All] - [Input confirm] and check the
connection of feeder cart. If any
problem is found, contact PFSC.
40023
Cart insertion check switch
remains OFF.
(Self-diagnosis error
occurred.)
Check the condition of the cart
insertion check switch.If any
problem is found, contact PFSC.
40024
Production end status has
not been reset.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Choose [Arrange] - [Production
Plan] and clear the Carried in PCB
count if Production Plan Set is
[ON] and Carried in PCB count
has reached the planned
production count.
2) Reset the production end signal
of the front stocker. If the error
persists even after the signal is
cleared, the connection of the line
cable may be at fault.
3) Since the remote production
mode is engaged, operation
cannot be started manually.
40025
2-1-2-11
NPM–W2 EJM7DE-MB-02-1T-00
3D Sensor Connection
Supply A Cover Open
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Supply side door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply side door if
opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply side
door.ON : Door closedOFF: Door
open
40026
Error detected in the 3D
sensor connection check.
(Self-diagnosis error
occurred.)
1) Make sure the 3D sensor is
connected properly.
2) On the PnP List window, make
sure the 3D sensor is installed.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
connection of the 3D sensor of the
detected table.
40028
2-1-2-12
NPM–W2 EJM7DE-MB-02-1T-00
Tape cover detection 4
Primary Source Power
Phase Connection
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 7
Error Code
Error Message
Cause Inspection and Solution
Primary power wiring may be
wrong.
(Self-diagnosis error
occurred.)
Make sure the primary power is
connected properly.
40029
Tape cover sensor 4 is
blocked.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Close the front cover of the tape
feeder.
2) Set the toggle lever of the tape
feeder properly.
3) Make sure that detection area of
the tape cover sensor is not
blocked by the top tape or big
component.
4) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check that the
feeder opening sensor 4 of the
table is OFF when the light from
the emitter is blocked, and ON
when the light from the emitter
reaches the detector. At this time,
make also sure that the green LED
is lit when the light from the emitter
is blocked, and the green and red
LEDs are lit when the light from
the emitter reaches the detector.
40035
2-1-2-13