NPM–W 2 EJM7DE-MB-02 -1T-00 Parts Re cognition Error Parts Re cognition Error Solutions to errors Error Code Error Message Cause Inspection and Solution Component height me asured through multi recognition camera is inva…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 41
Error Code
Error Message
Cause Inspection and Solution
Invalid brightness of
detected electrode.
- Electrode brightness varies
too much or is insufficient
because of crushed balls
with ball array components
or bent leads with lead
array components.This
error also occurs if the
recognition option:
brightness check results
NG. (Ans47 (51) error code
applies.)
(Recognition error -
Electrode brightness error)
Take any of the following measures:
1) Check the position and size of
the electrodes of the registered
component shape.Make sure that
unstable shape on the image other
than the electrodes is not
registered.
2) Check the image status of the
electrode.If the electrode of the
array electrode components is
partly dark, adjust the lamp value
so that the brightness of the
electrode will be uniform.
3) In case of the recognition error of
Ans47(51), make sure the position
or level registered in the
brightness check option is correct.
43047
2-1-3-80
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Component height measured
through multi recognition
camera is invalid.
(Recognition error
Component height
recognition anomaly)
1)Please confirm if each parameter
of component data is set correctly.
2)Please confirm if there is any
abnormality in component.
3)Please confirm the thick offset
maximum value/minimum value
when the thick measure is
selected to [ON].
4)Please execute the following
setting because the component
can't be height measured.Select
the 2D camera.Set the [Lead comp
reverse] option to OFF.Set the
thick measure to [OFF].
43048
Bad mark was judged to be
present in bad mark
recognition.
(Recognition error -
Detection error in target
marks for judgment)
If this error occurs at the position
with no bad marks during bad mark
recognition, check the mark
judgment area size, setting lamp
value and image TH value.Presence
of mark cannot be determined
reliably when using an unstable
location in the image.Perform
teaching so that there may be
difference in image stable enough to
determine the presence of mark.
43049
2-1-3-81
NPM–W2 EJM7DE-MB-02-1T-00
Rough Detect Error
(0)
Picture contrast Error
Error
Message
Troubleshooting
2-1-3
Single stop error 42
Error Code
Error Message
Cause Inspection and Solution
Failed to find threshold for
boundary detection.
(Insufficient dispensing error
occurred during priming shot
recognition.)
Take any of the following measures:
1) Execute eject check by
dispensing the material forcibly.
2) Perform priming shot teaching
and check the shot condition.
3) Correct the parameter(s) that
caused the error.
43501
No pattern detected during
boundary detection.
(Insufficient dispensing error
occurred during priming shot
recognition.)
Take any of the following measures:
1) Execute eject check by
dispensing the material forcibly.
2) Perform priming shot teaching
and check the shot condition.
3) Correct the parameter(s) that
caused the error.
43502