NPM–W 2 EJM7DE-MB-02 -1T-00 Parts Re cognition Error Solutions to errors Error Code Error Message Cause Inspection and Solution The ele ctrode arr ay of an electrode (lead or ball type) array component was no t properly …

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 37
Error Code
Error Message
Cause Inspection and Solution
Detected electrode count
does not agree with
registered count.Required
electrode count not
detected.Electrode in similar
shape detected around
registered electrode.
(Recognition error -
Electrode count)
Take any of the following measures:
1) Check the condition of the
component's electrodes.In case of
the error of Ans36 (30-39), an
error is detected when performing
detailed check. At this time, check
if the registered count of electrode
is correct.
2) Check the image status
(brightness) of component's
electrodes.In case of the error of
Ans36 (20-29), an error is detected
in the general positioning
processing of electrode
arrangement.At this time, check for
proper electrode size (width,
diameter), or check for proper
electrode image.If the electrodes
are unclear on the image, adjust
the lamp value.
43036
2-1-3-72

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
The electrode array of an
electrode (lead or ball type)
array component was not
properly detected because
either the electrode pitch or
quantity was determined to
be incorrect.The detected
electrode pitch does not
match input data.The input
quantity of electrodes were
not detected.
(Recognition error -
Electrode pitch or count)
Check the registered electrode
arrangement data (lead group, ball
group).Make sure the registered
shape data agrees with the actual
component image.Make sure the
registered arrays and pitches agree
with the actual component status.
43037
2-1-3-73

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 38
Error Code
Error Message
Cause Inspection and Solution
The detected electrode
pattern differs from the
registered pattern.The
required electrodes were not
detected.A shape similar to
an electrode was detected
near to a registered
electrode.This error also
occurs if an electrode is
detected in an unnecessary
location in recognition option:
unnecessary lead judgment.
(Recognition error -
Electrode array pattern)
Take any of the following measures:
1) Check the condition of the
component's electrodes.In case of
the error of Ans38 (30-39), an
error is detected when performing
detailed check.At this time, check
if the electrode arrangement data
is correct.On a particular note, with
Ans38 (35~39), processing for the
recognition option: unnecessary
lead judgment resulted that an
unnecessary electrode shape was
detected in an unregistered
position.
2) Check the image status
(brightness) of component's
electrodes.In case of error of
Ans38 (20~29), an error is
detected in the general positioning
processing of electrode
arrangement.At this time, check for
proper electrode size (width,
diameter), or check for proper
electrode image.If the electrodes
are unclear on the image, adjust
the lamp value.
43038
2-1-3-74