N7201A618E00_0309.pdf - 第227页

NPM–W 2 EJM7DE-MB-02 -1T-00 Communication : FROM Delete Error Communication Error Check Sum Error Head No. Error Solutions to errors Error Code Error Message Cause Inspection and Solution Error occurred in communication …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Timeout Error
Command processing
error
Over Current Anomaly
(R)
Encoder Disconnect
Anomaly
(R)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
29
Error Code
Error Message
Cause Inspection and Solution
Invalid motor encoder value.
(Head movement stopped.)
Check the connection between the
head motor and control board inside
the head and restart production.
Then, check the situation of the
error occurred and error message,
and contact PFSC.
1722
Current exceeding the
specified value has flown
during head movement.
(Abnormal voltage of current
was supplied to the head
motor.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1723
Communication error
occurred between the driver
and host. Cable between the
head motor and driver may
be broken.
(Error occurred in command
processing.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1724
No response from the head
or feeder cart^ etc.
(Communication timeout
error occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1725
2-1-4-57
NPM–W2 EJM7DE-MB-02-1T-00
Communication:
FROM Delete Error
Communication Error
Check Sum Error
Head No. Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the head
or feeder cart^ etc.
(Communication failure)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1726
Check sum error occurred in
the communication data from
the head or feeder cart^ etc.
to the host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1727
Improper procedure was
taken in software processing.
(Communication error
occurred.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1728
Improper procedure was
taken in software processing.
(Failed to clear FROM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1729
2-1-4-58
NPM–W2 EJM7DE-MB-02-1T-00
Communication:
Memory Allocation Error
Communication:
Address Setting Error
Communication:
FRAM Read Error
Communication:
FRAM Write Error
Communication:
FROM Mode Switch Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
30
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to switch to FROM
mode.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1730
Improper procedure was
taken in software processing.
(Failed to write data to
FRAM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1731
Improper procedure was
taken in software processing.
(Failed to read data from
FRAM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1732
Improper procedure was
taken in software processing.
(Failed to set communication
address.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1733
Improper procedure was
taken in software processing.
(Failed to secure memory.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1734
2-1-4-59