N7201A618E00_0309.pdf - 第259页

NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox MainSys PCB sk ip notification comma nd error Camera IF board DMA transfer error Camera IF board Exposure finish information deal error Camera IF board Exposure finish information start…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Camera IF board Camera
parameter set error
Camera IF board Light
spot correction table set
error
Camera IF board Binary
table set error
Camera IF board Camera
capture parameter error
Camera IF board
Initialization error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
45
Error Code
Error Message
Cause Inspection and Solution
Capture board could not be
initialized.
(Failed to initialize the
camera IF board.)
Check the connection of the camera
link cable between the inspection
head and inspection box.
1956
Improper procedure was
taken in software processing.
(Failed to obtain the capture
parameter.)
Restart the machine. If the error
persists, contact PFSC.
1957
Improper procedure was
taken in software processing.
(Failed to set the binary table
of the camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1958
Improper procedure was
taken in software processing.
(Failed to set the light spot
correction table of the
camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1959
Improper procedure was
taken in software processing.
(Failed to set the camera
parameters of the camera IF
board.)
Restart the machine. If the error
persists, contact PFSC.
1960
2-1-4-89
NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys PCB skip
notification command
error
Camera IF board DMA
transfer error
Camera IF board
Exposure finish
information deal error
Camera IF board
Exposure finish
information start error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to set the exposure
completion notice of the
camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1961
Exposure finish information
could not be received.
(Failed to receive the
exposure completion notice
of the camera IF board.)
Check the connection of the camera
link cable.
1962
Image transfer from the
camera IF board to the
inspection box PC failed.
(Failed in DMA transfer of
image from the camera IF
board.)
Check the connection of the camera
link cable.
2001
Improper procedure was
taken in software processing.
(PCB skip information
command notified
incorrectly.)
Restart the machine. If the error
persists, contact PFSC.
2002
2-1-4-90
NPM–W2 EJM7DE-MB-02-1T-00
Communication error
System state error
Command error
IspBox SubSys Sample
image save error
IspBox take image start
timeout
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
46
Error Code
Error Message
Cause Inspection and Solution
Because the IspBOX
process is delayed^ it has
been over the specified time
at the start of taking image.
(Image is taken in inspect
head after the light is off.)
Please restart the auto running. If
the error persists, contact PFSC.
2050
Needful image data lost in
saving sample image.
(Failed to save the sample
image.)
It is possible that the recognition is
wrong in the mark recognition
process.Please confirm the mark
recognition process.
2051
VLC system may be at fault.
(Command error detected by
VLC.)
Contact PFSC.
2053
VLC system may be at fault.
(System error detected by
VLC.)
Contact PFSC.
2054
Connector may be
disconnected.
(Communication error
detected by VLC.)
Check the connection connector.
2055
2-1-4-91