NPM–W 2 EJM7DE-MB-02 -1T-00 Power Box Heat Anomaly CPU Box Heat Anomaly Eject Conv Full Error Message Troubleshooting 2-1-3 Sing le stop er r o r 9 Error Code Error Message Cause Inspection and Solution Component eject c…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Eject Conv Full Notice
Eject Pallet Full
Eject Pallet Full Notice
Filter Clog Detect
Top Tape Exhaust
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Top tape is broken.
(Single stop error occurred.)
Reset the top tape properly.
40343
Filter clogged.
(Single stop error occurred.)
Clean the filter.
40344
Component eject pallet will
be full soon.
(Single stop error occurred.)
Remove the faulty components from
the component eject pallet.
40345
Component eject pallet is full.
(Single stop error occurred.)
Remove the components in the
component eject pallet.
- When the supply side is provided,
press the [Supply Complete] button.
- If not, choose [Arrange] - [Parts
prepare] - [Tray] - [Arrange] and
press the [Eject Pallet Clear] button.
40346
Component eject conveyor
will be full soon.
(Single stop error occurred.)
Remove NG components from the
eject conveyor.
40347
2-1-3-15
NPM–W2 EJM7DE-MB-02-1T-00
Power Box Heat Anomaly
CPU Box Heat Anomaly
Eject Conv Full
Error
Message
Troubleshooting
2-1-3
Single stop error 9
Error Code
Error Message
Cause Inspection and Solution
Component eject conveyor is
full.
(Single stop error occurred.)
Remove NG components from the
eject conveyor.
40348
Temperature in the CPU box
is high.
(Single stop error occurred.)
Make sure the cooling fan in the
bottom left of the box is turning.
40349
Cooling fan is at fault.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the cooling fan at left
side of bottom of the machine is
turning.
2) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
power box for proper
temperature.ON :NormalOFF:Hot
(abnormal)
3) Wait until the power box is cooled
down and restart the machine.
40350
2-1-3-16
NPM–W2 EJM7DE-MB-02-1T-00
Inspect Machine FB
Warning
Opening Sensor Det.
(L)
Opening Sensor Det.
(R)
Lead/Ball Float Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Component lead (or ball)
float detected by the 3D
sensor or multi recognition
camera.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the parameters of the
component data are set properly.
2) Check the components for any
problem.
40351
Obstacle detected at the
right NPM conveyor outer
opening sensor or left
opening sensor of the
adjoining machine.
(Single stop error occurred.)
Remove the obstacle from the right
NPM conveyor outer opening
sensor or left opening sensor of the
adjoining machine.
40352
Obstacle detected at the left
NPM conveyor outer opening
sensor or right opening
sensor of the adjoining
machine.
(Single stop error occurred.)
Remove the obstacle from the left
NPM conveyor outer opening
sensor or right opening sensor of
the adjoining machine.
40353
Same kind of error occurred
three times continuously at
each mounting point.
(Single stop error occurred.)
Check the error message and press
the Return button.
40354
2-1-3-17