N7201A618E00_0309.pdf - 第246页
NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox MainSys Inspection r esult us e memory ensure error IspBox MainSys Production dat a Read unfinished error IspBox MainSys Machine command Und efined error Error Message Troubleshooting 2…

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys Abnormal
PCB Support Holder
Down Error
PCB Support Holder Up
Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
PCB support holder failed to
rise within the prescribed
time.
(Error occurred in the PCB
support holder.)
1) Check the up/down of the PCB
support holder via the Output
confirm screen.
2) On the Input confirm screen,
check the condition of the
upper/lower limit sensors of PCB
support holder.
1862
PCB support holder failed to
lower within the prescribed
time.
(Error occurred in the PCB
support holder.)
1) Check the up/down of the PCB
support holder via the Output
confirm screen.
2) On the Input confirm screen,
check the condition of the
upper/lower limit sensors of PCB
support holder.
1864
Improper procedure was
taken in software processing.
(Inspection box software
failure occurred.)
Restart the machine. If the error
persists, contact PFSC.
1866
2-1-4-76

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys
Inspection result use
memory ensure error
IspBox MainSys
Production data Read
unfinished error
IspBox MainSys Machine
command Undefined error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
39
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper procedure was
taken in software
processing.
2) Mismatch of the software
version between the
machine and the inspection
box.
(Undefined command
notified from machine to
inspection box.)
Take any of the following measures:
1) Restart the machine. If the error
persists, contact PFSC.
2) If the error occurred after
upgrade, check the situation of the
error occurred and error message,
and contact PFSC.
1867
Improper procedure was
taken in software processing.
(Inspection box has not
loaded production data.)
Restart the machine. If the error
persists, contact PFSC.
1868
Improper procedure was
taken in software processing.
(Failed to secure memory for
saving inspection results.)
Restart the machine. If the error
persists, contact PFSC.
1869
2-1-4-77

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys
Production data View
information error
IspBox MainSys
Production start error
IspBox MainSys Busy
error
IspBox MainSys
Inspection result make
error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to create the
inspection result data.)
Restart the machine. If the error
persists, contact PFSC.
1870
Improper procedure was
taken in software processing.
(Next command cannot be
executed because current
command is in execution.)
Restart the machine. If the error
persists, contact PFSC.
1871
Production start command
was notified in mode other
than preparation.
(Production cannot be
started.)
Select the preparation mode.
1872
View data specified by
machine does not exist.
(View data unmatched
between the production data
in the machine and that
loaded by the inspection
box.)
Download the production data again.
1873
2-1-4-78