N7201A618E00_0309.pdf - 第38页
NPM–W 2 EJM7DE-MB-02 -1T-00 Tape cover detection 4 Primary Source Powe r Phase Connection Error Message Troubleshooting 2-1-2 Self-dia gnosis er r or s 7 Error Code Error Message Cause Inspection and Solution Primary pow…

NPM–W2 EJM7DE-MB-02-1T-00
3D Sensor Connection
Supply A Cover Open
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Supply side door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply side door if
opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply side
door.ON : Door closedOFF: Door
open
40026
Error detected in the 3D
sensor connection check.
(Self-diagnosis error
occurred.)
1) Make sure the 3D sensor is
connected properly.
2) On the PnP List window, make
sure the 3D sensor is installed.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
connection of the 3D sensor of the
detected table.
40028
2-1-2-12

NPM–W2 EJM7DE-MB-02-1T-00
Tape cover detection 4
Primary Source Power
Phase Connection
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 7
Error Code
Error Message
Cause Inspection and Solution
Primary power wiring may be
wrong.
(Self-diagnosis error
occurred.)
Make sure the primary power is
connected properly.
40029
Tape cover sensor 4 is
blocked.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Close the front cover of the tape
feeder.
2) Set the toggle lever of the tape
feeder properly.
3) Make sure that detection area of
the tape cover sensor is not
blocked by the top tape or big
component.
4) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check that the
feeder opening sensor 4 of the
table is OFF when the light from
the emitter is blocked, and ON
when the light from the emitter
reaches the detector. At this time,
make also sure that the green LED
is lit when the light from the emitter
is blocked, and the green and red
LEDs are lit when the light from
the emitter reaches the detector.
40035
2-1-2-13

NPM–W2 EJM7DE-MB-02-1T-00
Cover Open
Cover open
(Security sensor)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be broken.Contact
PFSC.
40036
Safety cover is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be broken.Contact
PFSC.
40037
2-1-2-14