NPM–W 2 EJM7DE-MB-02 -1T-00 Dispense Hea d θ Screw PCB Fuse Disc onnection Dispense Hea d θ Screw PCB Temperatur e Error Dispense Hea d θ Screw PCB Voltage Error Dispense Head Z PCB Fuse Disconne ction Dispense Head Z PC…

NPM–W2 EJM7DE-MB-02-1T-00
2-Nozzle Dispense Head
Z PCB Voltage Error
2-Nozzle Head PCB Fuse
Disconnection
2-Nozzle Head PCB
Temperature Error
2-Nozzle Head PCB
Voltage Error
8-Nozzle Head θ PCB
Fuse Disconnection
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fuse of the 8-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40060
Voltage at the 2-nozzle
mount head control board
has dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40061
CPU temperature at the 2-
nozzle mount head control
board has exceeded the
setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40062
Fuse of the 2-nozzle mount
head control board has
blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40063
Voltage at the 2-nozzle
dispense head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40064
2-1-2-22

NPM–W2 EJM7DE-MB-02-1T-00
Dispense Head θ Screw
PCB Fuse Disconnection
Dispense Head θ Screw
PCB Temperature Error
Dispense Head θ Screw
PCB Voltage Error
Dispense Head Z PCB
Fuse Disconnection
Dispense Head Z PCB
Temperature Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 12
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 2-
nozzle dispense head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Contact PFSC.
40065
Fuse of the 2-nozzle
dispense head Z-axis control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40066
Voltage at the 2-nozzle
dispense head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40067
CPU temperature at the 2-
nozzle dispense head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Contact PFSC.
40068
Fuse of the 2-nozzle
dispense head θ-axis control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40069
2-1-2-23

NPM–W2 EJM7DE-MB-02-1T-00
NCIO Board Temperature
Error
Inspection Head PCB 24V
Fuse Disconnection
Inspection Head PCB 5V
Fuse Disconnection
Inspection Head PCB
Light 24 Fuse
Disconnection
Inspection Head PCB
Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Voltage at the inspection
head light control board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40070
24V fuse of the inspection
head light control board has
blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40071
External 5V fuse of the
inspection head light control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40072
External 24V fuse of the
inspection head light control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40073
CPU temperature at the
NCIO board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40074
2-1-2-24