N7201A618E00_0309.pdf - 第284页

NPM–W 2 EJM7DE-MB-02 -1T-00 Other Error (Software Monitoring) Other Error (Communication) Other Error (Software) Other Error (Hardware) Other Error (Driver) Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Data Process Error
During Servo Alarm
During Interlock
SCIF(RFID)
Communication Error
Servo Amplifier
Communication Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the
servo amplifier.
(Failed to set the servo
amplifier parameters.)
Check the wiring connected to the
servo amplifier.If the error persists,
contact PFSC.
2188
Error occurred in
communication with the RFID
unit.
(Communication failure
occurred with the RFID unit.)
Check the wiring connected to the
RFID unit.If the error persists,
contact PFSC.
2189
Interlock worked.
(Interlock occurred.)
Release the interlock status.
2201
Connection between EM1
and SG is open.
(Servo alarm occurred.)
Ensure safety and reset the
emergency stop status.
2202
Improper procedure was
taken in software processing.
(Data processing error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
2203
2-1-4-114
NPM–W2 EJM7DE-MB-02-1T-00
Other Error
(Software Monitoring)
Other Error
(Communication)
Other Error
(Software)
Other Error
(Hardware)
Other Error
(Driver)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
58
Error Code
Error Message
Cause Inspection and Solution
Error with unanalyzable
cause occurred on the driver.
(Other error (driver)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2204
Error with unanalyzable
cause occurred on the
hardware.
(Other error (hardware)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2205
Error with unanalyzable
cause occurred on the
software.
(Other error (software)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2206
Error with unanalyzable
cause occurred in
communication.
(Other error (communication)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2207
Error with unanalyzable
cause occurred in software
monitoring.
(Other error (software
monitoring) occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2208
2-1-4-115
NPM–W2 EJM7DE-MB-02-1T-00
Servo Switch Off
Emergency Stop Switch
On
Air Pressure Abnormality
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Operation was attempted
when the supply air pressure
was abnormal.
(Abnormal air pressure
occurred.)
Take any of the following measures:
1)Please adjust the regulator when
the supplied air pressure is low.
Please refer to the operating
instruction(Maintenance
articles)about setting pressure.
2)If the air pressure detection
setting(Low limit setting) is too
high, error occurs. Please set the
air pressure detection value to
0.4MPa.
2209
Emergency stop switch has
been pressed.
(Emergency stop switch ON
error detected.)
Turn the emergency stop switch
clockwise to reset.(One position
each at front and rear)If the error
persists, the switch may be
broken.Contact PFSC.
2210
Operation was attempted
when the servo switch was
OFF.
(Servo switch turned OFF.)
Turn ON the servo switch (One
position each at front and rear).If the
error persists, the switch may be
broken. Choose [Machine] - [Adjust]
- [All] - [Input confirm] and make
sure the servo switch ON is
displayed when the servo switch is
ON and the Servo Off is shown
when the servo switch is OFF.
2211
2-1-4-116