N7201A618E00_0309.pdf - 第300页
NPM-W 2 EJM7DE-MB-03T-00 3-2-1 -9

NPM-W2 EJM7DE-MB-03T-00
3-2-1-8
Other individual evaluation/designated item errors
Code Description Cause Solution
46
Height (lifting) error of an electrode
or entire component
Error that arises upon confirmation
of a height abnormality by the 3D
sensor / Multi-recognition camera
(type 3).
1) Component error
2) Component data setting error
Check the target component
Check the component data
・Shape data position, size and
height judgment
47
Electrode unit brightness state error Error that arises when the
brightness state of aligned
electrodes is not even or that is
detected by brightness checking.
1) Component error (including
crushing of bumps)
2) Component data setting error
Check the target component
Check the component data
・Each shape data position/ size
brightness evaluation
49
Evaluation target mark detection
error
1) If a bad mark has been detected
with the bad mark recognition.
2) If a mark is not found at a given
location by polarity mark
checking.
Check the target component
Check the component data
・Brightness evaluation, polarity
checking
Other/Individual evaluation/ designated item errors
■
Solutions to
recognition

NPM-W2 EJM7DE-MB-03T-00
3-2-1-9

4 Load Arrangement
drawings