NPM–W 2 EJM7DE-MB-02 -1T-00 Upper System Interlock Error PinNzlC hanger recog er r SupportPin bcd mismatched SupportPin nzl n ot exist Solutions to errors Error Code Error Message Cause Inspection and Solution All nozzle…

NPM–W2 EJM7DE-MB-02-1T-00
SupportPin exchange
error
SupportPin mount error
SupportPin pick up error
SupportPin exist error
SupportPin unexist error
Error
Message
Troubleshooting
2-1-3
Single stop error 49
Error Code
Error Message
Cause Inspection and Solution
Failed to recognize support
pins.
(Single stop error occurred.)
Please return all support pin to the
home position in arrange
screen.Confirm if the dirt is adhered
to PCB support block surface and
support pin underside, please clean.
44018
There were support pins at
unnecessary positions.
(Single stop error occurred.)
Return all support pins to home
positions via the Arrange screen.
44019
Failed to pick up support pins.
(Single stop error occurred.)
Clean the nozzle and filter. Return
all support pins to home positions
via the Arrange screen.
44020
Failed to mount support pins.
(Single stop error occurred.)
Clean the nozzle and filter. Return
all support pins to home positions
via the Arrange screen.
44021
Failed to replace support
pins.
(Single stop error occurred.)
Make sure the support pins can be
replaced via the Arrange screen.
44022
2-1-3-96

NPM–W2 EJM7DE-MB-02-1T-00
Upper System Interlock
Error
PinNzlChanger recog err
SupportPin bcd
mismatched
SupportPin nzl not exist
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
All nozzles for support pin
replacement are set as bad
nozzle.
(Single stop error occurred.)
Clear the setting of bad nozzle.
44023
Invalid 2D barcode of the
nozzles for support pin
replacement.
(Single stop error occurred.)
Make sure the nozzle in the nozzle
changer for support pin replacement
is set correctly.
44024
Any of the following causes
is likely:
1) Nozzle changer mark for
support pin replacement is
out of camera's recognition
view.
2) Recognition error
occurred due to dirt on
mark^ etc.
(Single stop error occurred.)
Check the mark condition of the
nozzle changer for support pin
replacement.
44025
The interlock request is
arriving from upper system.
(Single stop error occurred.)
Please confirm the state of upper
system.
44026
2-1-3-97

NPM–W2 EJM7DE-MB-02-1T-00
F cart unconnected error
Moveable cover open error
Nzl Direction Setting Error
Tray Pos Offset Measure
Err
LNB nzl use interlock error
Error
Message
Troubleshooting
2-1-3
Single stop error 50
Error Code
Error Message
Cause Inspection and Solution
There is nozzle which has
been judged as unavailable
nozzle in LNB in nozzle
changer.
(Single stop error occurred.)
Please change the error nozzle to a
normal nozzle.
44027
Failed in tray position offset
measure.
(Single stop error occurred.)
Please execute tray pickup position1
and pickup position2 action in the
calibration 4th process.
44028
Changer nozzle direction
setting is wrong.
(Single stop error occurred.)
Please set the changer nozzle by
correct direction.
44029
|
44030
Because the F cart isn't
connected or the F moveable
cover is opening^ XY action
can't be executed.
(Interlock occurred.)
Please connect the F cart or close
the F moveable cover.
44031
2-1-3-98