N7201A618E00_0309.pdf - 第43页
NPM–W 2 EJM7DE-MB-02 -1T-00 Unknown Unit Detectio n (Chip thickness sensor) Unknown Unit Detectio n (Change r) Solutions to errors Error Code Error Message Cause Inspection and Solution Changer cann ot be detec ted. (Sel…

NPM–W2 EJM7DE-MB-02-1T-00
Unknown Unit Detection
(Supply section)
Unknown Unit Detection
(3D)
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 9
Error Code
Error Message
Cause Inspection and Solution
3D sensor cannot be
detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the 3D sensor is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
3D sensor is installed. If the error
persists, contact PFSC.
40043
Feeder unit cannot be
detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the unit is set properly
to the feeder carriage.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the feeder. If the
error persists, contact PFSC.
40044
2-1-2-17

NPM–W2 EJM7DE-MB-02-1T-00
Unknown Unit Detection
(Chip thickness sensor)
Unknown Unit Detection
(Changer)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Changer cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the changer is set
properly to the feeder carriage.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the changer. If
the error persists, contact PFSC.
40045
Chip thickness sensor
cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the chip thickness
sensor is set properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the chip
thickness sensor. If the error
persists, contact PFSC.
40046
2-1-2-18

NPM–W2 EJM7DE-MB-02-1T-00
12-nozzle head Z PCB
Voltage Error
Unknown Unit Detection
(Option lamp)
Unknown Unit Detection
(Height sensor)
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 10
Error Code
Error Message
Cause Inspection and Solution
Height measurement sensor
cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the height
measurement sensor is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the height
measurement sensor. If the error
persists, contact PFSC.
40047
Option light cannot be
detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the option light is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and check that the
option light is installed. If the error
persists, contact PFSC.
40048
Voltage at the 12-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40049
2-1-2-19