NPM–W 2 EJM7DE-MB-02 -1T-00 Command Execution Error Driver initialization incomplete Feeder Info rmation Get Error Feeder Pr eparation Error Solutions to errors Error Code Error Message Cause Inspection and Solution Feed…

NPM–W2 EJM7DE-MB-02-1T-00
Feeder Number Set Error
NG Eject Conveyer Action
Timeout
Communication:
(Common Slave):
Undefined Error
Communication:
(Common Slave):
System Section Error
Communication:
(Common Slave):
Communication Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
33
Error Code
Error Message
Cause Inspection and Solution
Check sum error occurred in
the communication data from
the head or feeder cart to the
host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting modules, and check the
wiring connected to them. If the
error persists, contact PFSC.
1763
Embedded software for each
board may be damaged.
(Check sum error occurred in
ROMless file.)
Read the ROMless file again and
restart production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1764
Improper procedure was
taken in software processing.
(Undefined error occurred.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1765
NG eject conveyor failed to
finish operation within the
prescribed time.
(NG eject conveyor failed to
operate properly.)
Check the NG eject conveyor for
proper movement using the
switches.If not, contact PFSC.
1766
Improper procedure was
taken in software processing.
(Feeder number error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1768
2-1-4-65

NPM–W2 EJM7DE-MB-02-1T-00
Command Execution Error
Driver initialization
incomplete
Feeder Information Get
Error
Feeder Preparation Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Feeder did not properly
return to origin during feeder
initialization due to some
trouble.
(Feeder preparation error
occurred.)
Make sure the tape reel is not
caught somewhere and there is no
foreign body on the pickup part.
Remove the feeder once and insert
it again to reset.Feed the tape
manually with the feed button and
make sure the tape runs smoothly.
1769
Error occurred in
communication with the
feeder. Feeder information
pointer is indeterminate value.
(Error occurred in obtaining
feeder information.)
Pull out and insert the feeder. If the
error persists, contact PFSC.
1771
Failing in driver initialization.
(Driver initialization
incomplete occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
1773
Another command was
issued while the first
command was being
executed.
(Command execution
disabled error occurred.)
Check the connection cable
between the driver and controller.
1775
2-1-4-66

NPM–W2 EJM7DE-MB-02-1T-00
Driver Alarm:
Abnormal Power Supply
Voltage
Driver Alarm:
Motor Step Out
Driver Alarm:
Origin Return Error
Driver Alarm:
System Setting
Uncompleted
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
34
Error Code
Error Message
Cause Inspection and Solution
Invalid driver setting.
(Driver alarm detected.)
Check the connection cable
between the driver and controller.
1776
Origin return for width
adjustment not completed.
(Driver alarm detected.)
Origin sensor may be at fault, or the
axis may have interfered with
something during width adjustment.
Check if the sensor detects any
foreign body properly.
1777
Pulse motor rotated beyond
the step-out range.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
Check the sliding parts such as ball
screw for any foreign matter that
can cause step-out.
1778
Power voltage dropped or
the driver may be at fault.
(Driver alarm detected.)
Check the power voltage of the
driver.
1779
2-1-4-67