N7201A618E00_0309.pdf - 第61页

NPM–W 2 EJM7DE-MB-02 -1T-00 16-Nozzle Head θ PCB Fuse Disconne ction 16-Nozzle Head θ PCB Temper ature Erro r 16-Nozzle Head θ PCB Voltage Error 16-Nozzle Head Z PCB Fuse Disconne ction 16-Nozzle Head Z PCB Temper ature …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
16-nozzle head Z PCB
Voltage Error
Carry In Again Production
Start Error(STOP)
Carry In Again Production
Start Error(END)
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 18
Error Code
Error Message
Cause Inspection and Solution
There is no PCB to be
reloaded on the reloading
conveyor.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Read the barcode information of
the PCB to be reloaded and put it
on the reloading conveyor.
2) If the error persists even after the
PCB is placed, the reloading
conveyor may be at fault.Contact
PFSC.
40108
There are PCBs on the
reload conveyor.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Remove the PCB from the
reloading conveyor.
2) If the error persists even after the
PCB is removed, the reloading
conveyor may be at fault.Contact
PFSC.
40109
Voltage at the 16-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40110
2-1-2-35
NPM–W2 EJM7DE-MB-02-1T-00
16-Nozzle HeadθPCB
Fuse Disconnection
16-Nozzle HeadθPCB
Temperature Error
16-Nozzle Head θPCB
Voltage Error
16-Nozzle Head Z PCB
Fuse Disconnection
16-Nozzle Head Z PCB
Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 16-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40111
Fuse of the 16-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40112
Voltage at the 16-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40113
CPU temperature at the 16-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40114
Fuse of the 16-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40115
2-1-2-36
NPM–W2 EJM7DE-MB-02-1T-00
Termal Regulator1
Communication Error
Termal Regulator2 Heater
Error
Termal Regulator1 Heater
Error
Termal Regulator2
Thermocouple Error
Termal Regulator1
Thermocouple Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 19
Error Code
Error Message
Cause Inspection and Solution
Miswiring^ broken wires or
short-circuit of the
thermocouple in the thermal
regulator
(Self-diagnosis error
occurred.)
Contact PFSC.
40116
Miswiring^ broken wires or
short-circuit of the
thermocouple in the thermal
regulator
(Self-diagnosis error
occurred.)
Contact PFSC.
40117
Broken heater cable or
disconnected heater
thermocouple.
(Self-diagnosis error
occurred.)
Contact PFSC.
40118
Broken heater cable or
disconnected heater
thermocouple.
(Self-diagnosis error
occurred.)
Contact PFSC.
40119
Error occurred in
communication between the
head board and the thermal
regulator board.
(Self-diagnosis error
occurred.)
Contact PFSC.
40120
2-1-2-37