N7201A618E00_0309.pdf - 第248页

NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox MainSys Production data Lot information error IspBox MainSys Production data Parts information error IspBox MainSys Mark corre ction Information register error Error Message Troubleshoo…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys
Production data View
information error
IspBox MainSys
Production start error
IspBox MainSys Busy
error
IspBox MainSys
Inspection result make
error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to create the
inspection result data.)
Restart the machine. If the error
persists, contact PFSC.
1870
Improper procedure was
taken in software processing.
(Next command cannot be
executed because current
command is in execution.)
Restart the machine. If the error
persists, contact PFSC.
1871
Production start command
was notified in mode other
than preparation.
(Production cannot be
started.)
Select the preparation mode.
1872
View data specified by
machine does not exist.
(View data unmatched
between the production data
in the machine and that
loaded by the inspection
box.)
Download the production data again.
1873
2-1-4-78
NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys
Production data Lot
information error
IspBox MainSys
Production data Parts
information error
IspBox MainSys Mark
correction Information
register error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
40
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to save mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1874
Check result data of the
component specified by the
machine does not exist.
(Production data (inspection
data) unmatched between
the machine and the
inspection box.)
Download the production data again.
1875
Lot data specified by the
machine does not exist.
(Lot data unmatched
between the machine and
the inspection box.)
Download the production data again.
1876
2-1-4-79
NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys Machine
communication error
IspBox MainSys Machine
communication error
IspBox MainSys
Production data Read
error
IspBox MainSys Machine
command Command
abnormal timing error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper procedure was
taken in software
processing.
2) Mismatch of the software
version between the
machine and the inspection
box.
(Production-related
command was notified from
the machine when
production was not
ongoing.)
Take measures shown with the
same number as that of the cause.
1) Restart the machine. If the error
persists, contact PFSC.
2) If the error persists even after the
upgrade, check the situation of the
error occurred and error message,
and contact PFSC.
1877
Production data cannot be
loaded.
(Failed to read production
data.)
Check the production data.
1878
Improper procedure was
taken in software processing.
(Failed to transmit command
to machine.)
Restart the machine. If the error
persists, contact PFSC.
1879
Improper procedure was
taken in software processing.
(Failed to receive command
from machine.)
Restart the machine. If the error
persists, contact PFSC.
1880
2-1-4-80