N7201A618E00_0309.pdf - 第69页

NPM–W 2 EJM7DE-MB-02 -1T-00 DC power FAN alarm Multi Recog Camera FAN alarm Multi Recog Cam temperature w arning Solutions to errors Error Code Error Message Cause Inspection and Solution CPU te mperature at the multi re…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Multi Recog Cam voltage
warning
LW16-Nozzle HeadθPCB
Fuse Disconnection
LW16-Nozzle HeadθPCB
Temperature Error
LW16-Nozzle HeadθPCB
Voltage Error
LW16-Nozzle Head Z PCB
Fuse Disconnection
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 22
Error Code
Error Message
Cause Inspection and Solution
Fuse of the LW16-nozzle
mount head Z-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40140
Voltage at the LW16-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40141
CPU temperature at the
LW16-nozzle mount head θ-
axis control board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40142
Fuse of the LW16-nozzle
mount head θ-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40143
Voltage at the multi recog
camera control board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40144
2-1-2-43
NPM–W2 EJM7DE-MB-02-1T-00
DC power FAN alarm
Multi Recog Camera FAN
alarm
Multi Recog Cam
temperature warning
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the multi
recog camera control board
has exceeded the setting
value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40145
Fan of the multi recog
camera stopped.
(Self-diagnosis error
occurred.)
Because obstacle interfere with the
fan of multi recognition camera
inside or the fan at fault, please
contact PFSC.
40146
Fan of the DC power
stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40147
2-1-2-44
NPM–W2 EJM7DE-MB-02-1T-00
PrePickup Insp comm err
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 23
Error Code
Error Message
Cause Inspection and Solution
The communication state is
abnormal among MC-LNB-
ISS(Inspection Server
Software).
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Please confirm the
communication state between MC
and LNB, LNB and ISS.
2)Please confirm state or setting of
LNB and ISS.
40157
2-1-2-45