N7201A618E00_0309.pdf - 第87页

NPM–W 2 EJM7DE-MB-02 -1T-00 Inspect Mac hine FB Warning Opening Sensor Det. (L) Opening Sensor Det. (R) Lead/Ba ll Float Error Solutions to errors Error Code Error Message Cause Inspection and Solution Component lead (or…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Power Box Heat Anomaly
CPU Box Heat Anomaly
Eject Conv Full
Error
Message
Troubleshooting
2-1-3
Single stop error 9
Error Code
Error Message
Cause Inspection and Solution
Component eject conveyor is
full.
(Single stop error occurred.)
Remove NG components from the
eject conveyor.
40348
Temperature in the CPU box
is high.
(Single stop error occurred.)
Make sure the cooling fan in the
bottom left of the box is turning.
40349
Cooling fan is at fault.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the cooling fan at left
side of bottom of the machine is
turning.
2) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
power box for proper
temperature.ON :NormalOFF:Hot
(abnormal)
3) Wait until the power box is cooled
down and restart the machine.
40350
2-1-3-16
NPM–W2 EJM7DE-MB-02-1T-00
Inspect Machine FB
Warning
Opening Sensor Det.
(L)
Opening Sensor Det.
(R)
Lead/Ball Float Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Component lead (or ball)
float detected by the 3D
sensor or multi recognition
camera.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the parameters of the
component data are set properly.
2) Check the components for any
problem.
40351
Obstacle detected at the
right NPM conveyor outer
opening sensor or left
opening sensor of the
adjoining machine.
(Single stop error occurred.)
Remove the obstacle from the right
NPM conveyor outer opening
sensor or left opening sensor of the
adjoining machine.
40352
Obstacle detected at the left
NPM conveyor outer opening
sensor or right opening
sensor of the adjoining
machine.
(Single stop error occurred.)
Remove the obstacle from the left
NPM conveyor outer opening
sensor or right opening sensor of
the adjoining machine.
40353
Same kind of error occurred
three times continuously at
each mounting point.
(Single stop error occurred.)
Check the error message and press
the Return button.
40354
2-1-3-17
NPM–W2 EJM7DE-MB-02-1T-00
Auto Product Change Err
Abnormal Pickup Height
Pickup Height Measure
Err
Error
Message
Troubleshooting
2-1-3
Single stop error 10
Error Code
Error Message
Cause Inspection and Solution
The head lowered to the soft
limit before detected by the
cushion end sensor^
because either the feeder or
tray was improperly set.
(Single stop error occurred.)
Make sure the feeder or pallet is set
properly. Make sure the nozzle is
attached to the head properly.
40355
Any of the following causes
is likely:
1) There is obstacle at the
pickup part.
2) Feeder not set.
3) Nozzle not attached.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove the obstacle from the
pickup part.
2) Set the feeder.
3) Attach the nozzle.
40356
Any of the following causes
is likely:
1) Failed to switch the
production data.
2) Failed to notify the
production changeover
information to the next
process machine.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Make sure the production data
can be loaded from the LNB.
2) Check the communication and
setting conditions of the next
process machine.
40357
2-1-3-18