N7201A618E00_0309.pdf - 第65页

NPM–W 2 EJM7DE-MB-02 -1T-00 Supply B Cover Open Magazine B Cover Open Solutions to errors Error Code Error Message Cause Inspection and Solution Magazine door is open. (Self-di agnosis erro r occurred. ) Take measures in…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Tray B Control Board Fuse
Disconnection
Tray B Control Board
Temperature Error
Tray B Control Board
Voltage Error
3-Nozzle Head PCB Fuse
Disconnection
3-Nozzle Head PCB
Temperature Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 20
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 3-
nozzle mount head control
board has exceeded the
setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40125
Fuse of the 3-nozzle mount
head control board has
blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40126
Voltage at the tray control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40127
CPU temperature at the tray
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40128
Fuse of the tray control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40129
2-1-2-39
NPM–W2 EJM7DE-MB-02-1T-00
Supply B Cover Open
Magazine B Cover Open
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Magazine door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply door if opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply
door.ON :Door closedOFF:Door
open
40130
Supply door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply door if opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply
door.ON :Door closedOFF:Door
open
40131
2-1-2-40
NPM–W2 EJM7DE-MB-02-1T-00
Safety Relay Reset is
abnormal.
Opposing Y Axis Posi
Error
(Opposing Supply No
Exist)
Opposing Y Axis Posi
Error
(Opposing Supply Exist)
Ceiling Fan2 Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 21
Error Code
Error Message
Cause Inspection and Solution
Ceiling fan stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with obstacles.
2) Make sure there is no
disconnected wire.
40132
Opposite X/Y axes stopped
within the range of the X/Y
axes.
(Self-diagnosis error
occurred.)
Move the opposite X/Y axes close to
the origin position manually.
40133
Opposite X/Y axes are out of
the turnout position.
(Self-diagnosis error
occurred.)
Move the opposite X/Y axes to the
turnout position manually.White
label is attached on the Y-axis as
the turnout position.Make sure that
the end of the X/Y axis falls within
the white label.
40134
Safety relay reset error
occurred. Since the safety
cover was opened for a
moment^ the safety relay
cannot be reset.
(Self-diagnosis error
occurred.)
Widely open the front or rear safety
cover once and then close it.
40135