N7201A618E00_0309.pdf - 第176页
NPM–W 2 EJM7DE-MB-02 -1T-00 Tape cover detection 4 (Front) Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s 4 Error Code Error Message Cause Inspection and Solution Tape cover sensor 4 is blocked. (Interloc…

NPM–W2 EJM7DE-MB-02-1T-00
Servo Switch Off
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Servo switch is OFF.
(Interlock occurred.)
Take measures in the following
order.
1) Turn the servo switch (One
position each at front and rear)
clockwise to turn it ON.
2) If the error persists even after the
servo switch is turned ON, the
switch may be broken.Contact
PFSC.
1315
2-1-4-6

NPM–W2 EJM7DE-MB-02-1T-00
Tape cover detection4
(Front)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
4
Error Code
Error Message
Cause Inspection and Solution
Tape cover sensor 4 is
blocked.
(Interlock occurred.)
Take any of the following measures:
1) Close the front cover of the tape
feeder.
2) Set the toggle lever of the tape
feeder properly.
3) Make sure that detection area of
the tape cover sensor is not
blocked by the top tape or big
component.
4) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check that the
feeder opening sensor 4 of the
table is OFF when the light from
the emitter is blocked and ON
when the light from the emitter
reaches the detector. At this time,
make also sure that the green LED
is lit when the light from the emitter
is blocked and the green and red
LEDs are lit when the light from
the emitter reaches the detector.
1316
2-1-4-7

NPM–W2 EJM7DE-MB-02-1T-00
Tape cover detection3
(Front)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Tape cover sensor 3 is
blocked.
(Interlock occurred.)
Take any of the following measures:
1) Close the front cover of the tape
feeder.
2) Set the toggle lever of the tape
feeder properly.
3) Make sure that detection area of
the tape cover sensor is not
blocked by the top tape or big
component.
4)Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check that the
feeder opening sensor 3 of the
table is OFF when the light from
the emitter is blocked and ON
when the light from the emitter
reaches the detector. At this time,
make also sure that the green LED
is lit when the light from the emitter
is blocked and the green and red
LEDs are lit when the light from
the emitter reaches the detector.
1317
2-1-4-8