N7201A618E00_0309.pdf - 第77页

NPM–W 2 EJM7DE-MB-02 -1T-00 Pick-up He ight Measure Error No Splicing Check Warn. No Splicing Check Solutions to errors Error Code Error Message Cause Inspection and Solution Any of the following causes is likely: 1) Spl…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Splicing Length Stop
Cover Open
PCB Position Error
Error
Message
Troubleshooting
2-1-3
Single stop error 4
Error Code
Error Message
Cause Inspection and Solution
PCB is removed or is not
placed at the correct position.
(Single stop error occurred.)
1) Set the PCB in position.
2) If the PCB is removed, press the
[PCB Remove] button.
40316
Safety cover is open.
(Single stop error occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
40317
Tape is getting low.
(Single stop error occurred.)
Perform tape splicing.
40318
2-1-3-6
NPM–W2 EJM7DE-MB-02-1T-00
Pick-up Height Measure
Error
No Splicing Check Warn.
No Splicing Check
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Splicing work not
performed.
2) Spliced part of the tape
has been recognized by
mistake.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Perform splicing work properly.
Make sure the reel is properly
installed and check the joint
detection sensor. Then, press the
Supply Complete button.
2) Cancel the joint detection.
40319
Any of the following causes
is likely:
1) Splicing work not
performed.
2) Spliced part of the tape
has been recognized by
mistake.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Perform splicing work properly.
Make sure the reel is properly
installed and check the joint
detection sensor. Then, press the
Supply Complete button.
2) Cancel the joint detection.
40320
Feeder or tray not set from
which the component is
picked up.
(Single stop error occurred.)
Make sure that the feeder or pallet is
properly set and the nozzle is
properly set on the head.
40321
2-1-3-7
NPM–W2 EJM7DE-MB-02-1T-00
PCB Warp Range Over
PCB Warp Measurement
Error
Part Thickness Measure
Error
Nozzle Height Measure
Error
PCB Thickness Measure
Error
Error
Message
Troubleshooting
2-1-3
Single stop error 5
Error Code
Error Message
Cause Inspection and Solution
Feeder or tray not set from
which the component is
picked up.
(Single stop error occurred.)
Make sure that the feeder or pallet is
properly set and the nozzle is
properly set on the head.
40322
Nozzle may be wrong.
(Single stop error occurred.)
Check the nozzle.
40323
Component height data may
be incorrect.
(Single stop error occurred.)
Check the component.
40324
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40325
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40326
2-1-3-8