N7201A618E00_0309.pdf - 第104页

NPM–W 2 EJM7DE-MB-02 -1T-00 Feeder Pull-out error Servo Switch Off Pick up error (VLC) Error Message Troubleshooting 2-1-3 Single stop er r or 18 Error Code Error Message Cause Inspection and Solution Any of the followin…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Shape of Parts err
(VLC)
Part Thick range ov
(VLC)
Part Thick det err
(VLC)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Measured nozzles and
measurement result
nozzles do not agree.
Scanning status of
measured component
affects the scan of other
nozzles.
2) Measurement result is out
of effective range of output
value of the vertical line
camera.
(Single stop error occurred.)
Make sure the component is set
properly and correct values of the
component data (component
dimensions, etc.) are set.
40406
Component thickness
measurement result is
beyond the threshold value of
thickness tolerance.
(Single stop error occurred.)
Check the upper and lower limits of
the thickness tolerance in the
mounting condition data of
component data.
40407
Invalid component pickup
status.
(Single stop error occurred.)
Check the component data
(component dimensions, etc.).Check
the pickup condition.
40408
2-1-3-33
NPM–W2 EJM7DE-MB-02-1T-00
Feeder Pull-out error
Servo Switch Off
Pick up error
(VLC)
Error
Message
Troubleshooting
2-1-3
Single stop error 18
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Incorrect component data
height
2) Improper component feed.
3) Incorrect feeder position.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Correct the component data.
2) Replace the tape feeder.
3) Choose [Production data] -
[Teach] - [Feeder] - [Pickup
position] and perform teaching of
the component pickup position.
40409
Servo switch turned OFF.
(Single stop error occurred.)
Take measures in the following
order.
1) Turn the servo switch clockwise
to turn it ON. (One position each at
front and rear)
2) If the error persists even after the
servo switch is tuned ON, the
switch may be broken.Contact
PFSC.
40410
Feeder was pulled out due to
a reason other than
component empty.
(Single stop error occurred.)
Set the feeder again.
40411
2-1-3-34
NPM–W2 EJM7DE-MB-02-1T-00
Parts verification Error
PCB Bar Code Recog
Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Recognition mark is out of
camera's view.
2) Recognition error
occurred due to dirt on PCB.
3) PCB barcode recognition
coordinates are incorrect.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Using the inching function, move
the camera to the recognition mark
position and press the [Re-
recognize] button.
2) After cleaning the recognition
camera and PCB, press the [Re-
recognize] button. If the
recognition error occurs again,
move the camera to the
recognition mark position with the
[Pass] button or inching function
and press the [Manual set] button.
[Pass]: Pass the PCBs.[Manual
set]: Saves the inching amount as
the offset.
3) Choose [Production data] -
[Correct] - [PCB] - [PCB recog.]
and enter the correct PCB barcode
recognition coordinates.
40412
Component verification failed.
(Single stop error occurred.)
Verify the components again.If
something is wrong, replace with the
correct component.
40413
2-1-3-35