N7201A618E00_0309.pdf - 第170页

NPM–W 2 EJM7DE-MB-02 -1T-00 Cover O pen (Rear Side Safety switch this side) Cover Open (Front Side Safety switch this side) Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s 1 Error Code Error Message Cause …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Timer safety relay
abnormal
R moveable cover open or
close action incomplete
error
F moveable cover open or
close action incomplete
error
R cart unconnected error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Because the R cart isn't
connected or the R moveable
cover is opening^ XY action
can't be executed.
(Interlock occurred.)
Please connect the R cart or close
the R moveable cover.
44032
Because the F moveable
cover open or close action is
incomplete^ XY action can't
be executed.
(Interlock occurred.)
Please confirm if the F moveable
cover action is executed correctly in
maintenance screen.
44033
Because the R moveable
cover open or close action is
incomplete^ XY action can't
be executed.
(Interlock occurred.)
Please confirm if the R moveable
cover action is executed correctly in
maintenance screen.
44034
Because the timer safety
relay is time out.
(Interlock occurred.)
Please connect the cart or close the
moveable cover.
44035
2-1-3-99
NPM–W2 EJM7DE-MB-02-1T-00
Cover Open
(Rear Side Safety switch
this side)
Cover Open
(Front Side Safety switch
this side)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
1
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1302
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1303
2-1-4-1
NPM–W2 EJM7DE-MB-02-1T-00
Safety Device Detect
(Post Proc)
Safety Device Detect
(Pre Proc)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Adjoining machine in the
previous process has been
turned OFF or emergency
stop switch has been
pressed.
(Interlock occurred.)
Take any of the following measures:
1) Turn ON power if the main switch
of the adjoining machine in the
previous process is OFF.
2) Reset the emergency stop switch
of the adjoining machine in the
previous machine if pressed.
1304
Adjoining machine in the
next process has been
turned OFF or emergency
stop switch has been
pressed.
(Interlock occurred.)
Take any of the following measures:
1) Turn ON power if the main switch
of the adjoining machine in the
next process is OFF.
2) Reset the emergency stop switch
of the adjoining machine in the
next process machine if pressed.
1305
2-1-4-2