N7201A618E00_0309.pdf - 第31页

NPM–W 2 EJM7DE-MB-02 -1T-00 Bad Head Re traction Position Error Bad Beam Retraction Position Error Magazine A Cover Open Solutions to errors Error Code Error Message Cause Inspection and Solution Magazine door is open. (…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Tape Cover Detection3
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 3
Error Code
Error Message
Cause Inspection and Solution
Tape cover sensor 3 is
blocked.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Close the front cover of the tape
feeder.
2) Set the toggle lever of the tape
feeder properly.
3) Make sure that detection area of
the tape cover sensor is not
blocked by the top tape or big
component.
4) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check that the
feeder opening sensor 3 of the
table is OFF when the light from
the emitter is blocked, and ON
when the light from the emitter
reaches the detector. At this time,
make also sure that the green LED
is lit when the light from the emitter
is blocked, and the green and red
LEDs are lit when the light from
the emitter reaches the detector.
40009
2-1-2-5
NPM–W2 EJM7DE-MB-02-1T-00
Bad Head Retraction
Position Error
Bad Beam Retraction
Position Error
Magazine A Cover Open
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Magazine door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the magazine door if
opened.
2) If the error persists, the safety
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the magazine door.
40010
Bad X/Y axes are not
positioned at the turnout
position.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Move the X/Y axes to the turnout
position (Front: Y-axis origin
position, rear: Y-axis minus soft
limit position).
2) If the error persists, contact
PFSC.
40011
Bad head not placed at the
turnout position.
(Self-diagnosis error
occurred.)
Move the head to the turnout (Z-axis
origin position).If the error persists,
contact PFSC.
40012
2-1-2-6
NPM–W2 EJM7DE-MB-02-1T-00
Firm version unmatched
error
Vacuum Pump Over Heat
Restart Error Occurred
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 4
Error Code
Error Message
Cause Inspection and Solution
Error occurred in the startup
process.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Restart the machine.
2) If the error persists, contact
PFSC.
40013
Any of the following causes
is likely:
1) Failure of the vacuum
pump
2) Improper setting of
overcurrent protection for
the thermal relay.
(Self-diagnosis error
occurred.)
Reset the thermal relay and choose
[Machine] - [Adjust] - [All] - [Output
confirm] to check the vacuum pump
for proper operation. If any problem
is found, contact PFSC.
40014
Mismatch between the
machine system and
firmware version.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Check the firmware version that
does not match the machine
system on the version information
window.
2) Install the appropriate version for
the system.
40015
2-1-2-7