NPM–W 2 EJM7DE-MB-02 -1T-00 Installed He ad Non- support Un it (HeadOptDrive Unit) No Installed Head Error Message Troubleshooting 2-1-2 Self-dia gnosis er r or s 8 Error Code Error Message Cause Inspection and Solution …

NPM–W2 EJM7DE-MB-02-1T-00
Cover Open
Cover open
(Security sensor)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be broken.Contact
PFSC.
40036
Safety cover is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be broken.Contact
PFSC.
40037
2-1-2-14

NPM–W2 EJM7DE-MB-02-1T-00
Installed Head Non-
support Unit
(HeadOptDriveUnit)
No Installed Head
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 8
Error Code
Error Message
Cause Inspection and Solution
Head not installed.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the head is set
properly.
2) Choose [Machine] - [Information]
- [PnP] and make sure the head is
installed. If the error persists,
contact PFSC.
40038
Different head option drive
unit (changer^ calibration
stage^ priming shot unit)
installed.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Make sure the head option drive
unit has been set properly.
2) When the mounting head is
installed, attach the changer.When
the inspection head is installed,
attach the calibration stage.When
the dispenser head is installed,
attach the priming shot unit.
3) Choose [Machine] - [Information]
- [PnP] - [List] and check the
connection of the head option drive
unit.
40039
2-1-2-15

NPM–W2 EJM7DE-MB-02-1T-00
Unknown Unit Detection
(Parts recognition camera)
Unknown Unit Detection
(Head)
Installed Head Non-
support Unit
(Tray)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Tray cannot be used with the
installed head.
(Self-diagnosis error
occurred.)
Replace the head with the one that
can use the tray.
40040
Head cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the head is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
head is installed. If the error
persists, contact PFSC.
40041
Parts recognition camera
cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the parts recognition
camera is set properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
parts recognition camera is
installed. If the error persists,
contact PFSC.
40042