NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 36
Error Code
Error Message
Cause Inspection and Solution
Electrode arrangement for
lead or ball array
components is
improper.Electrode column
arranged in linear on data is
not aligned.
(Recognition error -
Electrode arrangement)
Take any of the following measures:
1) Check the condition of the
component's electrodes.For lead
components, make sure there is
no variation in lead length.If the
lead length differs partly, register
the lead length of the component
concerned correctly.
2) Check the image status of the
electrode at the endsIf the shape
of the ends like J-lead component
or curved component is unclear on
the image, adjust the lamp value
and correct the image status.(At
this time, the side lighting is
effective.)
3) If the arrangement of ball array
components is not in lattice-
shaped, specify Shape property:
Irregular array ball.(At this time,
the ball data needs to be taught by
the machine.)
43033
2-1-3-70
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Lead length of lead array
components is not uniform
for lead column.Lead is
protruded partly for lead
arrangement.Bent
(straightened) lead
(Recognition error -
Electrode length)
Take any of the following measures:
1) Check the arrangement condition
of the component's electrodes.If
the lead length differs partly,
register the lead length of the
component concerned correctly.
2) Check the component pickup
position and pickup
condition.Make sure the
component pickup position is not
placed at the center and the
component is not likely to be in the
slanted pickup posture.
43034
Pitch between adjoining
electrodes for evenly spaced
array electrode components
is improper^ or entire length
of electrode arrangement is
invalid.This error also occurs
with unevenly spaced BGA
components^ if the detected
ball position deviates greatly
from the teaching position.
(Recognition error -
Electrode pitch)
Take any of the following measures:
1) Check the component for bent
lead.
2) Check the pitch data to be
registered.If the amount of bent
can be tolerated with the
component with actually bent lead,
specify the allowable lead bent
(pitch) of the recognition option.In
case of the error of Ans35 (35), the
entire length of electrode
arrangement is judged to be
invalid.In such a case, check the
pitch data to be registered.
43035
2-1-3-71
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 37
Error Code
Error Message
Cause Inspection and Solution
Detected electrode count
does not agree with
registered count.Required
electrode count not
detected.Electrode in similar
shape detected around
registered electrode.
(Recognition error -
Electrode count)
Take any of the following measures:
1) Check the condition of the
component's electrodes.In case of
the error of Ans36 (30-39), an
error is detected when performing
detailed check. At this time, check
if the registered count of electrode
is correct.
2) Check the image status
(brightness) of component's
electrodes.In case of the error of
Ans36 (20-29), an error is detected
in the general positioning
processing of electrode
arrangement.At this time, check for
proper electrode size (width,
diameter), or check for proper
electrode image.If the electrodes
are unclear on the image, adjust
the lamp value.