N7201A618E00_0309.pdf - 第122页

NPM–W 2 EJM7DE-MB-02 -1T-00 Parts Re cognition Error Parts Re cognition Error Error Message Troubleshooting 2-1-3 Single stop er r or 27 Error Code Error Message Cause Inspection and Solution Error occurred in the intern…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in image
taking processing.
(Recognition error - Image
taking error (head camera))
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43007
Error occurred in image
taking processing.
(Recognition error - Image
taking error (chip camera))
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43008
2-1-3-51
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 27
Error Code
Error Message
Cause Inspection and Solution
Error occurred in the internal
parameter required for image
taking.
(Parameter-related error in
loading recognition error
image)
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43009
Mismatch occurred in the
parameter used in the
internal processing of
recognition.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43010
2-1-3-52
NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Error in the combination of
shape data in recognition
data.
- Several electrodes
arranged in one position.
- Shape data set more than
the limit.
2) Shape or combination of
shapes not supported by
the current version of the
recognition system in use
has been specified.
- Unsupported shape data or
recognition option data has
been specified.
(Recognition error -
Combination of shape data)
Take any of the following measures:
1) Check the number of registered
shapes and check for multiple
shapes assigned to the same
mounting location.
2) Check the version of the
recognition system.
3) Send the recognition data and
image detail data to PFSC.
43011
Any of the following causes
is likely:
1) Error in the combination of
shape data in recognition
data.
- Several electrodes
arranged in one position.
- Shape data set more than
the limit.
2) Shape or combination of
shapes not supported by
the current version of the
recognition system in use
has been specified.
- Unsupported shape data or
recognition option data has
been specified.
(Recognition error -
Unsupported component
shape)
Take any of the following measures:
1) Check the number of registered
shapes and check for multiple
shapes assigned to the same
mounting location.
2) Check the version of the
recognition system.
3) Send the recognition data and
image detail data to PFSC.
43012
2-1-3-53