N7201A618E00_0309.pdf - 第288页
NPM–W 2 EJM7DE-MB-02 -1T-00 PartsD etectAfterMounting (VLCOutputDa ta out of validRangeErr) Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s 60 Error Code Error Message Cause Inspection and Solution Return …

NPM–W2 EJM7DE-MB-02-1T-00
Nozzle Change Error
EMG state detect
Invalid Mounted Points
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
System may be at fault.
(Mismatch occurred in
mounting finished points.)
Contact PFSC.
2223
Any of the following causes
is likely:
1) Emergency stop switch
has been pressed.
2) Safety cover is open.
3) Opening sensor detected.
(Emergency stop status
detected.)
Eliminate the cause of emergency
stop and restart production.
2224
Any of the following causes
is likely:
1) Improper shutter action at
nozzle changer
2) Improper cylinder action
3) Deformed or bent nozzle
(Nozzle change error
occurred when measure the
cart height .)
Take measures shown with the
same number as that of the cause.
1) Choose [Machine]-[Adjust]-
[Head]-[Nozzle exchange] and
open/close the nozzle changer.
Check for proper movement. If
stopped or caught on the way,
perform cleaning.
2) Replace the cylinder.
3) Replace the nozzle.
2225
2-1-4-118

NPM–W2 EJM7DE-MB-02-1T-00
PartsDetectAfterMounting
(VLCOutputData out of
validRangeErr)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
60
Error Code
Error Message
Cause Inspection and Solution
Return the output value
which exceeds allowable
range from VLC unit.
(Error occurred in parts
detect after mounting.)
1. Please confirm that there are no
parts dropped on the PCB.
2. Please confirm that there is no
dust(Parts etc.) on the setting
side of nozzle holder set in
nozzle changer.
3. Please confirm there is no dust
adhered to VLC unit.
4. If it can't be solved by above
1,2,3, please calibrate the VLC
unit.
2226
2-1-4-119

3 Solution to recognition