N7201A618E00_0309.pdf - 第46页
NPM–W 2 EJM7DE-MB-02 -1T-00 8-Nozzle Head θ PCB Temper ature Erro r 8-Nozzle Head θ PCB Voltage Error 8-Nozzle Head Z PCB Fuse Disconne ction 8-Nozzle Head Z PCB Temper ature Erro r 8-Nozzle Head Z PCB Voltage Error Erro…

NPM–W2 EJM7DE-MB-02-1T-00
12-Nozzle HeadθPCB
Fuse Disconnection
12-Nozzle HeadθPCB
Temperature Error
12-Nozzle Head θPCB
Voltage Error
12-Nozzle Head Z PCB
Fuse Disconnection
12-Nozzle Head Z PCB
Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 12-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40050
Fuse of the 12-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40051
Voltage at the 12-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40052
CPU temperature at the 12-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40053
Fuse of the 12-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40054
2-1-2-20

NPM–W2 EJM7DE-MB-02-1T-00
8-Nozzle Head θ PCB
Temperature Error
8-Nozzle Head θ PCB
Voltage Error
8-Nozzle Head Z PCB
Fuse Disconnection
8-Nozzle Head Z PCB
Temperature Error
8-Nozzle Head Z PCB
Voltage Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 11
Error Code
Error Message
Cause Inspection and Solution
Voltage at the 8-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40055
CPU temperature at the 8-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40056
Fuse of the 8-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40057
Voltage at the 8-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40058
CPU temperature at the 8-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40059
2-1-2-21

NPM–W2 EJM7DE-MB-02-1T-00
2-Nozzle Dispense Head
Z PCB Voltage Error
2-Nozzle Head PCB Fuse
Disconnection
2-Nozzle Head PCB
Temperature Error
2-Nozzle Head PCB
Voltage Error
8-Nozzle Head θ PCB
Fuse Disconnection
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fuse of the 8-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40060
Voltage at the 2-nozzle
mount head control board
has dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40061
CPU temperature at the 2-
nozzle mount head control
board has exceeded the
setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40062
Fuse of the 2-nozzle mount
head control board has
blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40063
Voltage at the 2-nozzle
dispense head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40064
2-1-2-22