NPM–W 2 EJM7DE-MB-02 -1T-00 No Priming shot unit No Ch anger uni t Error Message Troubleshooting 2-1-2 Self-dia gnosis er r or s 5 Error Code Error Message Cause Inspection and Solution Nozzle change r not installed. (Se…

NPM–W2 EJM7DE-MB-02-1T-00
Air Pressure Error
Momentary Power OFF
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Power supply may have
been stopped momentarily
due to power failure.
(Self-diagnosis error
occurred.)
Check the voltage of the power
supply in the plant. Turn ON the
power and resume production. If the
error persists, contact PFSC.
40016
Abnormal air pressure.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Please adjust the regulator when
the supplied air pressure is low.
Please refer to the operating
instruction(Maintenance
articles)about setting pressure.
2)If the air pressure detection
setting(Low limit setting) is too
high, error occurs. Please set the
air pressure detection value to
0.4MPa.
40017
2-1-2-8

NPM–W2 EJM7DE-MB-02-1T-00
No Priming shot unit
No Changer unit
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 5
Error Code
Error Message
Cause Inspection and Solution
Nozzle changer not installed.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Install the unit corresponding to
the head.
2) If the error persists even after the
unit is installed, the connection
with the unit may not be
detected.Choose [Machine] -
[Adjust] - [All] - [Input confirm] and
check the connection of units.
40018
Priming shot unit not
installed.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Install the unit corresponding to
the head.
2) If the error persists even after the
unit is installed, the connection
with the unit may not be
detected.Choose [Machine] -
[Adjust] - [All] - [Input confirm] and
check the connection of units.
40019
2-1-2-9

NPM–W2 EJM7DE-MB-02-1T-00
Lack of necessary
Nozzles for Production
(Bad Nozzle)
No Proof stage
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Calibration plate stage not
installed.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Install the unit corresponding to
the head.
2) If the error persists even after the
unit is installed, the connection
with the unit may not be
detected.Choose [Machine] -
[Adjust] - [All] - [Input confirm] and
check the connection of units.
40020
Bad nozzles more than the
judgment value. Or required
nozzle is set as bad nozzle.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Choose [Machine] - [Set] - [Line
Camera/Multi Recognition
Camera] - [Action Parameter] and
check if the judgment value is
correct.
2) Choose [Machine] - [Set] - [Head]
- [Bad head] and identify the cause
(pickup error or recognition error).
Then perform appropriate
maintenance and clear the setting
of the bad nozzle.
40021
2-1-2-10