N7201A618E00_0309.pdf - 第109页

NPM–W 2 EJM7DE-MB-02 -1T-00 Loacl Height Result Range Err Mount point recog error Solutions to errors Error Code Error Message Cause Inspection and Solution Any of the following causes is likely: 1) R ecognition mark is …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Stamper return origin
Error
Stamper unit initial error
The trans unit is not set up.
Error
Message
Troubleshooting
2-1-3
Single stop error 20
Error Code
Error Message
Cause Inspection and Solution
Transcript unit cannot be
confirmed.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the transcript unit is
set properly.
2) Remove and insert the transcript
unit.
40421
Failed to Initialize the
transcript unit properly.
(Single stop error occurred.)
Take any of the following measures:
1) Check the transcript unit.
2) Remove the transcript unit and
insert it again.
40422
Failed to return the transcript
unit to origin properly.
(Single stop error occurred.)
Take any of the following measures:
1) Check the transcript unit.
2) Remove the transcript unit and
insert it again.
40423
2-1-3-38
NPM–W2 EJM7DE-MB-02-1T-00
Loacl Height Result
Range Err
Mount point recog error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Recognition mark is out of
camera's view.
2) Recognition error
occurred due to dirt on
PCB^ etc.
3) Incorrect mounting point
recognition coordinates
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Using the inching function, move
the camera to the recognition mark
position and press the [Re-
recognize] button.
2) After cleaning the recognition
camera and PCB, press the [Re-
recognize] button. If the
recognition error occurs again,
press the [No Recognition] or
[Pass] button. [No Recognition]:
Move to the next action without
recognition. [Pass]: Pass the PCB.
3) Choose [Production data] -
[Correct] - [Mount] and enter the
correct mounting point recognition
coordinates.
40424
There are variations in height
measurement results.
(Single stop error occurred.)
Take any of the following measures:
1) Check the PCB.
2) Check the setting value of the
spot height result tolerance.
40425
2-1-3-39
NPM–W2 EJM7DE-MB-02-1T-00
Nozzle barcode recog
error
Syringe trans empty
Trans auto-supply error
Trans material empty
Height Measurement Error
Error
Message
Troubleshooting
2-1-3
Single stop error 21
Error Code
Error Message
Cause Inspection and Solution
Error occurred during
measurement of height
sensor.
(Single stop error occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
40426
Material in the transcript table
is insufficient.
(Single stop error occurred.)
Supply the material to the stamper
table.
40427
Any of the following causes
is likely:
1) Tip of the syringe is
clogged.
2) Transcript material for the
syringe is insufficient.
3) Syringe not installed
properly.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the tip of the syringe.
2) Supply transcript material to the
syringe.
3) Make sure the syringe is installed.
40428
Transcript material in the
syringe is insufficient.
(Single stop error occurred.)
Supply transcript material to the
syringe.
40429
Nozzle in the changer to be
used for production does not
agree with the one saved in
the production data.
(Single stop error occurred.)
Check the barcode of the target
nozzle in the changer.
40430
2-1-3-40