N7201A618E00_0309.pdf - 第262页
NPM–W 2 EJM7DE-MB-02 -1T-00 Sensor Blocked partly Outlines overflow System error Head unconn ected Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s 47 Error Code Error Message Cause Inspection and Solution …

NPM–W2 EJM7DE-MB-02-1T-00
Optical path deviated
Low light intensity
Effective Section overflow
Line number overflow
Sensor Blocked
completely
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
1) Sensor is blocked
completely by some
obstacles.
2) Connector may be
disconnected.
(VLC sensor blocked
completely.)
1) Remove any obstacles. Wipe
away any dirt from the lens if it is
dirty.
2) Check the connector.
2056
VLC system may be at fault.
(Line overflow detected by
VLC.)
Contact PFSC.
2057
VLC system may be at fault.
(Overflow from effective zone
detected by VLC.)
Contact PFSC.
2100
Lens may be dirty.
(Drop in intensity detected by
VLC.)
Clean the lens if dirt is found.
2101
Optical axis is displaced.
(Displacement of the optical
axis detected.)
Check the installation condition of
the VLC sensor.
2103
2-1-4-92

NPM–W2 EJM7DE-MB-02-1T-00
Sensor Blocked partly
Outlines overflow
System error
Head unconnected
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
47
Error Code
Error Message
Cause Inspection and Solution
VLC system may be at fault.
(Unconnected head
detected.)
Contact PFSC.
2105
VLC system may be at fault.
(System error detected.)
Contact PFSC.
2107
VLC system may be at fault.
(Shell count detected by VLC
overflowed.)
Contact PFSC.
2108
Any of the following causes
is likely:
1) Sensor is blocked partly
by some obstacles.
2)Connector may be
disconnected.
(VLC sensor blocked partly.)
Take measures shown with the
same number as that of the cause.
1)Remove any obstacles. Wipe
away any dirt from the lens if it is
dirty.
2) Check the connector.
2109
2-1-4-93

NPM–W2 EJM7DE-MB-02-1T-00
Machine parameter check
sum error
IspBox Unconnected Err
(Ready signal undetected
when starting)
Inspector Box
communication error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Inspection box has not
been connected.
2) Power was turned OFF
without shutting down the
machine on the last
occasion.
(Communication with the
inspection box cannot be
confirmed.)
Take measures shown with the
same number as that of the cause.
1) Check the connection of the
inspection box.
2) Turn OFF power once and turn it
back ON in one minute.
2111
Ready signal of the
inspection box failed to be
detected.
(Start-up of inspection box
not detected.)
Take any of the following measures:
1) Check the connection of the
inspection box.
2) Turn OFF power once and turn it
back ON in one minute.
3) If the error persists, contact
PFSC. It is possible to product
without inspection if set to ON the
bad beam of the inspect head.
2112
Improper procedure was
taken in software processing.
(Check sum error occurred in
the machine parameter.)
Return to the main menu and restart
production. If the error persists,
contact PFSC.
2115
2-1-4-94