NPM–W 2 EJM7DE-MB-02 -1T-00 Safety Device Detec t (Post Proc) Safety Device Detec t (Pre Proc) Solutions to errors Error Code Error Message Cause Inspection and Solution Adjoining machine in the previous process has been…

NPM–W2 EJM7DE-MB-02-1T-00
Cover Open
(Rear Side Safety switch
this side)
Cover Open
(Front Side Safety switch
this side)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
1
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1302
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1303
2-1-4-1

NPM–W2 EJM7DE-MB-02-1T-00
Safety Device Detect
(Post Proc)
Safety Device Detect
(Pre Proc)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Adjoining machine in the
previous process has been
turned OFF or emergency
stop switch has been
pressed.
(Interlock occurred.)
Take any of the following measures:
1) Turn ON power if the main switch
of the adjoining machine in the
previous process is OFF.
2) Reset the emergency stop switch
of the adjoining machine in the
previous machine if pressed.
1304
Adjoining machine in the
next process has been
turned OFF or emergency
stop switch has been
pressed.
(Interlock occurred.)
Take any of the following measures:
1) Turn ON power if the main switch
of the adjoining machine in the
next process is OFF.
2) Reset the emergency stop switch
of the adjoining machine in the
next process machine if pressed.
1305
2-1-4-2

NPM–W2 EJM7DE-MB-02-1T-00
Momentary Power OFF
Cover Open
(Rear Side Safety switch
interior side)
Cover Open
(Front Side Safety switch
interior side)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
2
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1306
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1307
Power supply may have
been stopped momentarily
due to power failure.
(Interlock occurred.)
Check the voltage of the power
supply in the plant. Turn the
machine power back ON and start
production. If the error persists,
contact PFSC.
1308
2-1-4-3