N7201A618E00_0309.pdf - 第54页

NPM–W 2 EJM7DE-MB-02 -1T-00 Y Axis Servo Amp Fan Error X Axis Servo Amp Fan Error Servo Amp External Fan Error Error Message Troubleshooting 2-1-2 Self-dia gnosis er r or s 15 Error Code Error Message Cause Inspection an…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
P9Case Temperature
Error
P9Case Fan Error
P9 Power Fan Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fan of the P9 controller
power stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40089
Fan of the P9 controller case
stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40090
Inside temperature of the P9
controller case is higher than
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40091
2-1-2-28
NPM–W2 EJM7DE-MB-02-1T-00
Y Axis Servo Amp Fan
Error
X Axis Servo Amp Fan
Error
Servo Amp External Fan
Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 15
Error Code
Error Message
Cause Inspection and Solution
External fan of the XY servo
amplifier stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40092
Fan of the X-axis servo
amplifier stopped
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40093
Fan of the Y-axis servo
amplifier stopped
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40094
2-1-2-29
NPM–W2 EJM7DE-MB-02-1T-00
Operation Switch Board
Temperature Error
Fan Error Under Base
Ceiling Fan Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Ceiling fan stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40095
Fan under the base stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40096
CPU temperature at the
operation switch board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40097
2-1-2-30